In a randomized controlled trial David van der Ham and colleagues investigate induction of labor versus expectant management for women with preterm prelabor rupture of membranes.
Introduction
When women with a previous cesarean section and an unfavorable cervix have an indication for delivery, the choice is to induce labor or to perform a cesarean section. This study aims to assess the effectiveness and safety of a balloon catheter as a method of induction of labor in women with one previous cesarean section and an unfavorable cervix compared with an elective repeat cesarean section.
Material and methods
We performed a prospective cohort study in 51 hospitals in the Netherlands on term women with one previous cesarean section, a live singleton fetus in cephalic position, an unfavorable cervix and an indication for delivery. We recorded obstetric, maternal and neonatal characteristics. We compared the outcome of women who were induced with a balloon catheter with the outcome of women who delivered by elective repeat cesarean section. Main outcomes were maternal and neonatal morbidity. Mode of delivery was a secondary outcome for women who were induced. Adjusted odds ratios (aOR) were calculated using logistic regression, adjusted for potential confounders.
Results
Analysis was performed on 993 women who were induced and 321 women who had a repeat cesarean section (August 2011 until September 2012). Among the women who were induced, 560 (56.4%) delivered vaginally and 11 (1.1%) sustained a uterine rupture. Composite adverse maternal outcome (uterine rupture, severe postpartum hemorrhage or postpartum infection) occurred in 73 (7.4%) in the balloon and 14 (4.5%) women in the repeat cesarean section group (aOR 1.58, 95% confidence interval [CI] 0.85‐2.96). Composite adverse neonatal outcome (Apgar score <7 at 5 minutes or umbilical pH <7.10) occurred in 57 (5.7%) and 10 (3.2%) neonates, respectively (aOR 1.40, 95% CI 0.87‐3.48). Women who were induced had a shorter postpartum admission time (2.0 vs 3.0 days (P < 0.0001)).
Conclusions
In women with a previous cesarean section and a need for delivery, induction of labor with a balloon catheter does not result in a significant increase in adverse maternal and neonatal outcomes as compared with planned cesarean section.
BackgroundPreterm prelabour rupture of the membranes (PPROM) is an important clinical problem and a dilemma for the gynaecologist. On the one hand, awaiting spontaneous labour increases the probability of infectious disease for both mother and child, whereas on the other hand induction of labour leads to preterm birth with an increase in neonatal morbidity (e.g., respiratory distress syndrome (RDS)) and a possible rise in the number of instrumental deliveries.Methods/DesignWe aim to determine the effectiveness and cost-effectiveness of immediate delivery after PPROM in near term gestation compared to expectant management. Pregnant women with preterm prelabour rupture of the membranes at a gestational age from 34+0 weeks until 37+0 weeks will be included in a multicentre prospective randomised controlled trial. We will compare early delivery with expectant monitoring.The primary outcome of this study is neonatal sepsis. Secondary outcome measures are maternal morbidity (chorioamnionitis, puerperal sepsis) and neonatal disease, instrumental delivery rate, maternal quality of life, maternal preferences and costs. We anticipate that a reduction of neonatal infection from 7.5% to 2.5% after induction will outweigh an increase in RDS and additional costs due to admission of the child due to prematurity. Under these assumptions, we aim to randomly allocate 520 women to two groups of 260 women each. Analysis will be by intention to treat. Additionally a cost-effectiveness analysis will be performed to evaluate if the cost related to early delivery will outweigh those of expectant management. Long term outcomes will be evaluated using modelling.DiscussionThis trial will provide evidence as to whether induction of labour after preterm prelabour rupture of membranes is an effective and cost-effective strategy to reduce the risk of neonatal sepsis.Controlled clinical trial registerISRCTN29313500
For our primary outcome, no difference was observed between the Foley catheter balloon filled with 60mL and the one filled with 30mL. Yet, a Foley catheter filled with 60mL was associated in multiparous women with a higher rate of deliveries within eight hours after amniotomy and in nulliparous with a significantly lower caesarean section rate. These latest findings should be interpreted with cautious as underpowered.
In women with pregnancies complicated by PPROM near term, induction of labor does not reduce neonatal sepsis, whereas costs associated with this strategy are probably higher.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.