The objective of this study was to investigate the safety and performance of AQUACEL™ Ag+ dressing, a wound dressing containing a combination of anti-biofilm and antimicrobial agents, in the management of chronic wounds. Patients (n = 42) with venous leg ulcers exhibiting signs of clinical infection were treated for 4 weeks with AQUACEL™ Ag+ dressing, followed by management with AQUACEL™ wound dressings for 4 weeks. Wound progression, wound size, ulcer pain and clinical evolution of the wound were assessed for up to 8 weeks. Adverse events were recorded throughout the study. AQUACEL™ Ag+ dressing had an acceptable safety profile, with only one patient discontinuing from the study, because of a non-treatment-related adverse event. After 8 weeks, substantial wound improvements were observed: 5 patients (11·9%) had healed ulcers and 32 patients (76·2%) showed improvement in ulcer condition. The mean ulcer size had reduced by 54·5%. Patients reported less pain as the study progressed. Notable improvements were observed in patients with ulcers that were considered to require treatment with systemic antibiotics or topical antimicrobials at baseline (n = 10), with a mean 70·2% reduction in wound area. These data indicate that AQUACEL™ Ag+ dressing has an acceptable safety profile in the management of venous leg ulcers that may be impeded by biofilm.
Extracorporeal Membrane Oxygenation (ECMO) is a well-established method of support in patients with severe respiratory and/or circulatory failure. Unfortunately, this invasive method of treatment is associated with a high risk of neurological complications including brain death. Proper diagnosis of brain death is crucial for the termination of futile medical care. Currently, the legal system in Poland does not provide an accepted protocol for apnea tests for patients on ECMO support. Veno-arterial ECMO is particularly problematic in this regard because it provides both gas exchange and circulatory support. CO 2 elimination by ECMO prevents hypercapnia, which is required to perform an apnea test. Several authors have described a safe apnea test procedure in patients on ECMO. Maximal reduction of the sweep gas flow to the oxygenator should maintain an acceptable haemoglobin oxygenation level and reduce elimination of carbon dioxide. Hypercapnia achieved via this method should allow an apnea test to be conducted in the typical manner. In the case of profound desaturation and an inadequate increase in the arterial CO 2 concentration, the sweep gas flow rate may be increased to obtain the desired oxygenation level, and exogenous carbon dioxide may be added to achieve a target carbon dioxide level. Incorporation of an apnea test for ECMO patients is planned in the next edition of the Polish guidelines on the determination of brain death.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.