Background Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) causing coronavirus disease 2019 (COVID-19) is currently finally determined in laboratory settings by real-time reverse-transcription polymerase-chain-reaction (rt-PCR). However, simple testing with immediately available results are crucial to gain control over COVID-19. The aim was to evaluate such a point-of-care antigen rapid test (AG-rt) device in its performance compared to laboratory-based rt-PCR testing in COVID-19 suspected, symptomatic patients. Methods For this prospective study, two specimens each of 541 symptomatic female (54.7%) and male (45.3%) patients aged between 18 and 95 years tested at five emergency departments (ED, n = 296) and four primary healthcare centres (PHC, n = 245), were compared, using AG-rt (positive/negative/invalid) and rt-PCR (positive/negative and cycle threshold, Ct) to diagnose SARS-CoV-2. Diagnostic accuracy, sensitivity, specificity, positive predictive values (PPV), negative predictive value (NPV), and likelihood ratios (LR+/-) of the AG-rt were assessed. Results Differences between ED and PHC were detected regarding gender, age, symptoms, disease prevalence, and diagnostic performance. Overall, 174 (32.2%) were tested positive on AG-rt and 213 (39.4%) on rt-PCR. AG correctly classified 91.7% of all rt-PCR positive cases with a sensitivity of 80.3%, specificity of 99.1%, PPV of 98.3, NPV of 88.6%, LR(+) of 87.8, and LR(-) of 0.20. The highest sensitivities and specificities of AG-rt were detected in PHC (sensitivity: 84.4%, specificity: 100.0%), when using Ct of 30 as cut-off (sensitivity: 92.5%, specificity: 97.8%), and when symptom onset was within the first three days (sensitivity: 82.9%, specificity: 99.6%). Conclusions The highest sensitivity was detected with a high viral load. Our findings suggest that AG-rt are comparable to rt-PCR to diagnose SARS-CoV-2 in COVID-19 suspected symptomatic patients presenting both at emergency departments and primary health care centres.
BackgroundSevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2) causing coronavirus disease 2019 (COVID-19) is currently finally determined in laboratory settings by real-time reverse-transcription polymerase-chain-reaction (rt-PCR). However, simple testing with immediately available results are crucial to gain control over COVID-19. The aim was to evaluate such a point-of-care antigen rapid test (AG-rt) device in its performance compared to laboratory-based rt-PCR testing in COVID-19 suspected, symptomatic patients.MethodsFor this prospective study, two specimens each of 541 symptomatic female (54.7%) and male (45.3%) patients aged between 18 and 95 years tested at five emergency departments (ED, n=296) and four primary healthcare centres (PHC, n=245), were compared, using AG-rt (positive/negative/invalid) and rt-PCR (positive/negative and cycle threshold, Ct) to diagnose SARS-CoV-2. Diagnostic accuracy, sensitivity, specificity, positive predictive values (PPV), negative predictive value (NPV), and likelihood ratios (LR+/-) of the AG-rt were assessed.ResultsDifferences between ED and PHC were detected regarding gender, age, symptoms, disease prevalence, and diagnostic performance. Overall, 174 (32.2%) were tested positive on AG-rt and 213 (39.4%) on rt-PCR. AG correctly classified 91.7% of all rt-PCR positive cases with a sensitivity of 80.3%, specificity of 99.1%, PPV of 98.3, NPV of 88.6%, LR(+) of 87.8, and LR(-) of 0.20. The highest sensitivities and specificities of AG-rt were detected in PHC (sensitivity: 84.4%, specificity: 100.0%), when using Ct of 30 as cut-off (sensitivity: 92.5%, specificity: 97.8%), and when symptom onset was within the first three days (sensitivity: 82.9%, specificity: 99.6%).ConclusionsThe highest sensitivity was detected with a high viral load. Our findings suggest that AG-rt are comparable to rt-PCR to diagnose SARS-CoV-2 in COVID-19 suspected symptomatic patients presenting both at emergency departments and primary health care centres.SUMMARYThe rapid SARS-Cov-2 antigen test (SARS-CoV-2 Rapid Antigen Test (Roche Diagnostics), was compared in symptomatic patients with PCR testing both in emergency departments and primary health care centres. It showed an overall sensitivity of 80.3% and specificity of 99.1%; these were higher with lower PCR cycle threshold numbers and with a shorter onset of symptoms.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.