ABO-incompatible (ABO-i) kidney transplantation (KT) has emerged for overcoming the shortage of organ donors. Although this technique initially achieved only low graft survival due to isoagglutinin, recently developed desensitization protocols have improved survival to levels that are comparable to ABO-compatible KT. However, isoagglutinin is still regarded as a major obstacle to ABO-i KT. In this study, we evaluate the impact of isoagglutinin titer on clinical outcomes as well as factors that may influence isoagglutinin titers. In total, data from 95 patients who underwent ABO-i KT were analyzed. Preoperatively, rituximab administration and plasmapheresis were performed until the titer was reduced to ≤1:4. Retrospective analysis included blood group; timing and dosage of rituximab; isoagglutinin titer; number of plasmapheresis; and clinical outcomes including graft survival and serum creatinine. Graft survival was 95.8% (n = 91) and average serum creatinine at 1- and 1.5-year post-ABOi-KT was 1.3. Three patients died of sepsis. The identified predictors of titer-rebound after transplant were short interval (<7 days) between rituximab and first plasmapheresis (P = 0.004); high initial titer (≥256) (P = 0.023); low titer-reduction rate (P < 0.001); and blood group O (P < 0.001). One patient who experienced a rebound developed antibody-mediated rejection. With low-dose (200 mg) rituximab, the change in isoagglutinin titer-rebound was not significant and the infection rate was significantly decreased (P = 0.001). In conclusion, isoagglutinin titer-rebound within the first 2 weeks after KT may be a risk factor for rejection. The factors identified as affecting titer-rebound after KT were high initial isoagglutinin titer, low titer-reduction rate, short interval, and blood group O.
BackgroundThe therapeutic efficacy of red blood cell (RBC) transfusions in patients with autoimmune hemolytic anemia (AIHA) is highly debated because of speculations on the increased risk of transfusion reactions; yet it is a suggested adjuvant therapy in anemic patients with life-threatening hypoxemia. In this study, we evaluated the safety and efficacy of RBC transfusions in AIHA patients.MethodsDaily changes in hemoglobin, total bilirubin, and lactate dehydrogenase (LDH) were assessed in 161 AIHA patients without bleeding history who were transfused once with 1-5 units of the least-incompatible RBCs and monitored over a seven-day period. Post-transfusion patients positive for alloantibodies only or those without RBC-specific antibodies were considered as control groups (N=100 for both groups).ResultsThe three groups revealed similar increases in hemoglobin of 1.40-1.70 g/dL (autoantibodies), 1.20-1.60 g/dL (alloantibodies only), and 1.40-1.55 g/dL (no antibodies) for seven days following transfusion of 10 mL RBCs/kg. During follow-up, no significant changes in total bilirubin or LDH levels were detected in the AIHA group compared with controls. Influences due to autoantibody type, direct antiglobulin test (DAT) specificity and strength, and steroid therapy status on transfusion reactions were not evident in AIHA patients. In addition, changes in hemoglobin levels were significantly higher (P<0.001) in severe anemia (<5 g/dL) than in other patients.ConclusionsTransfusion of the least-incompatible RBCs in AIHA patients is effective and safe without any associated increase in hemolysis risk when compared with post-transfusion patients positive for alloantibodies or those lacking RBC-specific antibodies.
TPE effectively removed plasma bilirubin and improved coagulation function in EAD patients, with higher survival in the TPE group than in the non-TPE group. TPE may be an effective liver support for EAD patients. J. Clin. Apheresis 32:147-153, 2017. © 2016 Wiley Periodicals, Inc.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.