The potential cancer risk associated with long‐term exposure to angiotensin receptor blockers (ARBs) is still unclear. We assessed the risk of incident cancer among hypertensive patients who were treated with ARBs compared with patients exposed to angiotensin‐converting enzyme inhibitors (ACEIs), which are known to have a neutral effect on cancer development. Using the Korean National Health Insurance Service database, we analyzed the data of patients diagnosed with essential hypertension from January 2005 to December 2012 who were aged ≥40 years, initially free of cancer, and were prescribed either ACEI or ARB (n = 293,962). Cox proportional hazard model adjusted for covariates was used to evaluate the risk of incident cancer. During a mean follow‐up of 10 years, 24,610 incident cancers were observed. ARB use was associated with a decreased risk of overall cancer compared with ACEI use (hazard ratio [HR] 0.76, 95% confidence interval [CI] 0.72‐0.80). Similar results were obtained for lung (HR 0.73, 95% CI 0.64‐0.82), hepatic (HR 0.56, 95% CI 0.48‐0.65), and gastric cancers (HR 0.74, 95% CI 0.66‐0.83). Regardless of the subgroup, greater reduction of cancer risk was seen among patients treated with ARB than that among patients treated with ACEIs. Particularly, the decreased risk of cancer among ARB users was more prominent among males and heavy drinkers (interaction P < .005). Dose‐response analyses demonstrated a gradual decrease in risk with prolonged ARB therapy than that with ACEI use. In conclusion, ARB use was associated with a decreased risk of overall cancer and several site‐specific cancers.
Background Little is known about age-specific target blood pressure (BP) in hypertensive patients with diabetes mellitus (DM). The aim of this study was to determine the BP level at the lowest cardiovascular risk of hypertensive patients with DM according to age. Methods Using the Korean National Health Insurance Service database, we analyzed patients without cardiovascular disease diagnosed with both hypertension and DM from January 2002 to December 2011. Primary end-point was composite cardiovascular events including cardiovascular death, myocardial infarction and stroke. Results Of 241,148 study patients, 35,396 had cardiovascular events during a median follow-up period of 10 years. At the age of < 70 years, the risk of cardiovascular events was lower in patients with BP < 120/70 mmHg than in those with BP 130–139/80–89 mmHg. At the age of ≥ 70, however, there were no significant differences in the risk of cardiovascular events between patients with BP 130–139/80–89 mmHg and BP < 120/70 mmHg. The risk of cardiovascular events was similar between patients with BP 130–139/80–89 mmHg and BP 120–129/70–79 mmHg, and it was significantly higher in those with BP ≥ 140/90 mmHg than in those with BP 130–139/80–89 mmHg at all ages. Conclusions In a cohort of hypertensive patients who had DM but no history of cardiovascular disease, lower BP was associated with lower risk of cardiovascular events especially at the age of < 70. However, low BP < 130–139/80–89 mmHg was not associated with decreased cardiovascular risk, it may be better to keep the BP of 130–139/80–89 mmHg at the age of ≥ 70.
Background: Hand grip strength (HGS) has been associated with cardiovascular events. However, the exact mechanism responsible for the inverse association between HGS and cardiovascular events has not been established. The aim of this study was to assess whether arterial stiffness mediates this association.Methods: We studied 1508 participants (age; 60 AE 5, men; 47.5%) from the Ansan cohort of the Korean Genome Epidemiology Study. Participants were assessed for various parameters of arterial stiffness as well as HGS. The augmentation index (AIx) and brachial-ankle pulse wave velocity (baPWV) were evaluated by using an applanation tonometer and automated waveform analyzer, respectively. Carotid intima medial thickness (IMT) was measured by B-mode ultrasonogram with a 7.5-MHz linear array transducer. HGS was evaluated using a Jamar dynamometer.Results: With increased grip strength, AIx decreased (r ¼ 0.437, P < 0.001). baPWV (r ¼ 0.044, P ¼ 0.107) and carotid IMT (r ¼ 0.005, P ¼ 0.856) had no significant correlation with grip strength. This trend was consistently observed regardless of hypertension, but was more pronounced in participants with hypertension. Conclusion:HGS was significantly correlated with AIx, but not with baPWV and carotid IMT. Our findings suggest that central arterial stiffness could mediate the association between HGS and cardiovascular events.
Background : The aim of the study was to establish a new syphilis test algorithm using Architect Syphilis TP (Abbott Japan, Japan: AST), a fully automated treponemal antibody test, as a screening test in a university hospital laboratory. We evaluated performance characteristics of AST in various patient groups.Methods : A total of 1,357 serum samples obtained from patients at a university hospital from June to August, 2008 were categorized into checkup, preoperative, other diseases, diagnosis (clinically suspected of syphilis), and follow up groups. We compared the results of AST with those of RPR (N=1,276) or Treponema pallidum hemagglutination assay (TPHA, N=81). Samples with discrepant results between RPR or TPHA and AST were retested by fluorescent treponemal antibody absorption test (FTA-ABS) and all patients' clinical records were thoroughly reviewed.Results : The positive rate of AST was significantly higher than that of RPR in preoperative and other diseases groups and was the same as that of RPR in diagnosis group. There were no significant differences in check up and follow up groups. The results of AST showed 97.4% (1,243/1,276) and 97.5% (79/81) concordance rates with those of RPR and TPHA, respectively. Among 26 RPR-AST discrepant and FTA-ABS confirmed cases, there were 20 RPR false-negatives, 4 RPR falsepositives, 1 AST false-negative, and 1 AST false-positive.Conclusions : Based on the results and literature review, we established a new syphilis test algorithm using AST as a screening test, which would be helpful for detection of more syphilis patients including latent infections. (Korean J Lab Med 2008;28:475-82)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.