In transfomerless photovoltaic (PV) grid-connected inverter application, to reduce leakage current and to increase efficiency, many inverter topologies have been proposed. The method for increasing efficiency and reducing leakage current is evaluated and analysed in the present study. The operation of transfomerless PV inverter topologies with high-performance such as full-bridge, H5, H6, HERIC and paralleled-buck topology is analysed to calculate switching losses, conduction losses and free-wheeling losses. Device total losses for inverter topology are calculated according to the switching frequency and the output power. Also, a novel high-frequency model of inverter topology is proposed using the leg voltage and high-frequency equivalent circuit. The relation between the parasitic capacitor voltage and its leakage current is explained using the proposed high-frequency model. Also, the magnitude of the high-frequency voltage in the parasitic capacitor is derived mathematically. Efficiency of the several inverter topology according to the output power is compared and the leakage current is analysed using a novel high-frequency model. Finally, the efficiency and leakage current analysis are verified by simulation tool and 3 kW prototype.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.