User gait phase estimation plays a key role for the seamless control of the lower-limb robotic assistive devices (e.g., exoskeletons or prostheses) during ambulation. To achieve this, several studies have attempted to estimate the gait phase using a thigh or shank angle. However, their estimation resulted in some deviation from the actual walking and varied across the walking speeds. In this study, we investigated the different setups using for the machine learning approach to obtain more accurate and consistent gait phase estimation for the robotic transfemoral prosthesis over different walking speeds. Considering the transfemoral prosthetic application, we proposed two different sensor setups: i) the angular positions and velocities of both thigh and torso (S1) and ii) the angular positions and velocities of both thigh and torso, and heel force data (S2). The proposed setups and method are experimentally evaluated with three healthy young subjects at four different walking speeds: 0.5, 1.0, 1.5, and 2.0 m/s. Both results showed robust and accurate gait phase estimation with respect to the ground truth (loss value of S1: 4.54e-03 Vs. S2: 4.70e-03). S1 had the advantage of a simple equipment setup using only two IMUs, while S2 had the advantage of estimating more accurate heel-strikes than S1 by using additional heel force data. The choice between the two sensor setups can depend on the researchers' preference in consideration of the device setup or the focus of the interest.
Impedance controllers are popularly used in the field of lower limb prostheses and exoskeleton development. Such controllers assume the joint to be a spring-damper system described by a discrete set of equilibria and impedance parameters. Said parameters are estimated via a least squares optimization that minimizes the difference between the controller's output torque and human joint torque. Other researchers have used perturbation studies to determine empirical values for ankle impedance. The resulting values vary greatly from the prior least squares estimates. While perturbation studies are more credible, they require immense investment. This paper extended the least squares approach to reproduce the results of perturbation studies. The resulting impedance parameters were successfully tested on a powered transfemoral prosthesis, AMPRO II. Further, the paper investigated the effect of multiple equilibria on the least square estimation and the performance of the impedance controller. Finally, the paper uses the the proposed least squares optimization method to estimate knee impedance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.