The use of high-permittivity materials has been shown to be an effective method for increasing transmit and receive sensitivity in areas of low-signal intensity in the brain at high field. Results in this article show that the use of these materials does not increase the intercoil coupling for a phased array receive coil, does not have any detrimental effects on the B 0 homogeneity within the brain, and does not affect the specific absorption rate distribution within the head. Areas of the brain close to the pads exhibit significant increases (>100%) in transmit field efficiency, but areas further away show a less pronounced (~10%) decrease due to the homogenization of the transmit field and the loss introduced by the dielectric pads. Magn Reson Med 67:1285-1293,
Since the invention of arterial spin labeling (ASL) it has been acknowledged that ASL does not allow reliable detection of a white matter (WM) perfusion signal. However, recent developments such as pseudo-continuous labeling and background suppression have improved the quality. The goal of this research was to study the ability of these newer ASL sequences to detect WM perfusion signal. Background suppressed pseudo-continuous ASL was implemented at 3T with multislice 2D readout after 1525 ms. In five volunteers it was shown that 10 min scanning resulted in significant perfusion signal in 70% of WM voxels. Increasing the labeling and delay time did not lead to a higher percentage. In 27 normal volunteers it was found that 35 averages are necessary to detect significant WM signal, but 150 averages are needed to detect signal in the deep WM. Finally, it was shown in a patient with a cerebral arteriovenous malformation that pseudo-continuous ASL enabled the depiction of hypointense WM perfusion signal, although dynamic susceptibility contrast MRI showed that this region was merely showing delayed arrival of contrast agent than hypoperfusion. It can be concluded that, except within the deep WM, ASL is sensitive enough to detect WM perfusion signal and perfusion deficits. Magn Reson Med 62:165-173, 2009.
The longitudinal relaxation time of blood is a crucial parameter for quantification of cerebral blood flow by arterial spin labeling and is one of the main determinants of the signal-to-noise ratio of the resulting perfusion maps. Whereas at low and medium magnetic field strengths (B0), its in vivo value is well established; at ultra-high field, this is still uncertain. In this study, longitudinal relaxation time of blood in the sagittal sinus was measured at 1.5 T, 3 T, and 7 T. A nonselective inversion pulse preceding a Look-Locker echo planar imaging sequence was performed to obtain the inversion recovery curve of venous blood. The results showed that longitudinal relaxation time of blood at 7 T was ∼ 2.1 s which translates to an anticipated 33% gain in the signal-to-noise ratio in arterial spin labeling experiments due to T1 relaxation alone compared with 3 T. In addition, the linear relationship between longitudinal relaxation time of blood and B0 was confirmed.
High permittivity ''dielectric pads'' have been shown to increase image quality at high magnetic fields in regions of low radiofrequency transmit efficiency. This article presents a series of electromagnetic simulations to determine the effects of pad size and geometry, relative permittivity value, as well as thickness on the transmit radiofrequency fields for neuroimaging at 7 T. For a 5-mm thick pad, there is virtually no effect on the transmit field for relative permittivity values lower than~90. Significant improvements are found for values between 90 and 180. If the relative permittivity is increased above~180 then areas of very low transmit efficiency are produced. For a 1-cm thick pad, the corresponding numbers are~60 and~120, respectively. Based upon the findings, a new material (barium titanate, relative permittivity~150) is used to produce thin (~5 mm) dielectric pads which can easily be placed within a standard receive head array. Experimental measurements of transmit sensitivities, as well as acquisition of T 2 -and T 2 *-weighted images show the promise of this approach. Magn Reson Med 67:912-918,
Intra-and multicenter reproducibility of currently used arterial spin labeling (ASL) methods were assessed at three imaging centers in the Netherlands, equipped with Philips 3TMR scanners. Six healthy participants were scanned twice at each site. The imaging protocol consisted of continuous ASL (CASL), pseudo-continuous ASL (p-CASL) with and without background suppression, pulsed ASL (PASL) with single and multiple inversion times (TIs), and selective ASL for segmentation. Reproducibility was expressed in terms of the coefficient of repeatability and the repeatability index. Voxelwise analysis of variance was performed, yielding brain maps that reflected regional variability. Intra-and multicenter reproducibility were comparable for all methods, except for single TI PASL, with better intracenter reproducibility (F-test of equality of two variances, P < 0.05). Pseudocontinuous ASL and multi TI PASL varied least between sites. Variability maps of all methods showed most variability near brain-feeding arteries within sessions and in gray matter between sessions. On the basis of the results of this study, one could consider the use of reference values in clinical routine, with whole-brain p-CASL perfusion varying < 20% over repeated measurements within the same individuals considered to be normal. Knowledge on regional variability allows for the use of perfusion-weighted images in the assessment of local cerebral pathology.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.