In this multicentre study, LAAO with the ACP showed high procedural success and a favourable outcome for the prevention of AF-related thromboembolism. Modification in antithrombotic therapy after LAAO may result in reduction of bleeding events.
Background Chronic obstructive pulmonary disease (COPD) is increasingly considered a heterogeneous condition. It was hypothesised that COPD, as currently defined, includes different clinically relevant subtypes. Methods To identify and validate COPD subtypes, 342 subjects hospitalised for the first time because of a COPD exacerbation were recruited. Three months after discharge, when clinically stable, symptoms and quality of life, lung function, exercise capacity, nutritional status, biomarkers of systemic and bronchial inflammation, sputum microbiology, CT of the thorax and echocardiography were assessed. COPD groups were identified by partitioning cluster analysis and validated prospectively against cause-specific hospitalisations and all-cause mortality during a 4 year follow-up. Results Three COPD groups were identified: group 1 (n¼126, 67 years) was characterised by severe airflow limitation (postbronchodilator forced expiratory volume in 1 s (FEV 1 ) 38% predicted) and worse performance in most of the respiratory domains of the disease; group 2 (n¼125, 69 years) showed milder airflow limitation (FEV 1
This randomized study suggests that p-cond during primary PCI does not reduce infarct size or improve myocardial function recovery at both short- and long-term follow-up and might have a potential harmful effect.
In patients with nonvalvular atrial fibrillation at high risk of cardioembolic events and absolute contraindications to anticoagulation, LAAC using the ACP device followed by dual-/single-antiplatelet therapy was associated with a low rate of embolic and bleeding events after a mean follow-up of 20 months. No cases of severe residual leak or device thrombosis were observed at the 6-month follow-up.
Following successful left atrial appendage closure with the Amplatzer Cardiac Plug, the presence of peri-device leak was relatively low, and device-associated thrombus was infrequent. Neither was associated with increased risk for thromboembolism.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.