Multifocal visual evoked potentials (mfVEP) were recorded with a pattern-reversing display that modulated only the long wavelength-sensitive (L) cones or only the middle wavelength-sensitive (M) cones. Outside the central 5.8 degrees (radius), the ratio of the amplitudes of the mfVEP responses to L- and M-cone modulation varied across the six subjects, ranging from 1.1 to 1.7. The responses from the central 1 degrees (radius) showed a substantially lower ratio, ranging from 0.8 to 1.1 (average of 0.9). The variation among individuals outside the central fovea is probably due to differences in the ratio of the L/M cone input to both magno- and parvocellular pathways. The substantially lower ratios for the central responses is consistent with an L/M cone ratio closer to 1.0 in the central 1 degrees and/or an adjustment in the gain of the L- versus M-cone contributions to the central parvocellular pathways. Taking into consideration evidence from other techniques, we believe it is unlikely that most individuals have a L/M cone ratio of 1.0 in the fovea. Instead, it appears that there is a change in gain before the mfVEP is generated in area 17.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.