This paper presents a new approach of eddy current methods for determining the size of the co-axial hole in the metallic circular disk. In recent decades, for the air-cored sensor probe, the impedance change due to the presence of an infinite metal plate can be calculated by the Dodd-Deeds model. However, in practical measurements, the sample cannot match with the condition required - ‘infinite’, thus the Dodd-Deeds model could not be applied to the disk with finite size and certainly not a co-axial hole in the center. In this paper, a dual-constraint analytical method is proposed. That is, the upper and lower limits of the integration are substituted with specific values instead of the original 0 and . Besides, it is found that, once the outer radius of the disk is fixed (i.e. the lower limit of integration is fixed), the upper limit reduces linearly as the size of the coaxial hole increases. Both the FEM simulation and experiments have been carried out to validate this method. The radius of the hole can be estimated based on the dual-constraint integration feature.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.