A hydrogen cyanide laser interferometer is mostly used to measure the plasma electron density in many Tokamak devices. The real-time calculation system of the plasma electron density based on a field-programmable gate array is proposed in this work. An Altera EP4CE30F23C8 FPGA chip is selected as the master chip, and an AD9238 chip of 10 MSps is employed for analog-to-digital conversion. The FPGA-based adapted Fast Fourier Transform and the proposed processing algorithm are designed to obtain the plasma electron density. The calculated density is stored in the secure digital card and can also be transmitted to the plasma control system via Ethernet. The experimental results show that the proposed system can effectively obtain the plasma density. The maximum error range is from -1 to 1 degree and the time resolution is 0.025 ms which is better than that of the convention method 0.1 ms. Meanwhile, this system is highly flexible and reduces design costs to meet the demands of Tokamak devices.
Plasma electron density is one of the most fundamental parameters when studying tokamak plasma physics, which is widely used in plasma control systems and plasma physics analyses. A hydrogen cyanide laser interferometer is generally applied to measure the plasma electron density in many tokamak devices. Therein, the plasma electron density is calculated by measuring the phase difference between the reference signal and the detector signal. This work provides a new way to realize real-time measurements of the plasma electron density with a phase comparator and processing system based on a field-programmable gate array chip. The system integrates a signal processing module, an all-phase fast Fourier transform (ap-FFT) module realized via matrix operations and phase comparisons, and a network communication module all in one board. This work concludes that the ap-FFT is robust and accurate for phase calculations compared with a windowing FFT. A data-reuse method and a phase shift method are proposed to improve the time resolution and phase range. The phase error is less than 0.1° and the time resolution is 0.025 ms, which is better than hardware methods and traditional software methods. This system is highly flexible with reduced design costs to meet the requirements of a tokamak, which can provide a valuable reference for other tokamak and phase difference comparisons.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.