BackgroundThis study develops a model-based myocardial T1 mapping technique with sparsity constraints which employs a single-shot inversion-recovery (IR) radial fast low angle shot (FLASH) cardiovascular magnetic resonance (CMR) acquisition. The method should offer high resolution, accuracy, precision and reproducibility.MethodsThe proposed reconstruction estimates myocardial parameter maps directly from undersampled k-space which is continuously measured by IR radial FLASH with a 4 s breathhold and retrospectively sorted based on a cardiac trigger signal. Joint sparsity constraints are imposed on the parameter maps to further improve T1 precision. Validations involved studies of an experimental phantom and 8 healthy adult subjects.ResultsIn comparison to an IR spin-echo reference method, phantom experiments with T1 values ranging from 300 to 1500 ms revealed good accuracy and precision at simulated heart rates between 40 and 100 bpm. In vivo T1 maps achieved better precision and qualitatively better preservation of image features for the proposed method than a real-time CMR approach followed by pixelwise fitting. Apart from good inter-observer reproducibility (0.6% of the mean), in vivo results confirmed good intra-subject reproducibility (1.05% of the mean for intra-scan and 1.17, 1.51% of the means for the two inter-scans, respectively) of the proposed method.ConclusionModel-based reconstructions with sparsity constraints allow for single-shot myocardial T1 maps with high spatial resolution, accuracy, precision and reproducibility within a 4 s breathhold. Clinical trials are warranted.Electronic supplementary materialThe online version of this article (10.1186/s12968-019-0570-3) contains supplementary material, which is available to authorized users.
The comprehensive model-based reconstruction with L1 regularization offers rapid and robust T mapping with high accuracy and precision. The method warrants accelerated computing and online implementation for extended clinical trials. Magn Reson Med 79:730-740, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Noradrenaline is a neurotransmitter involved in general arousal, selective attention, memory, inflammation, and neurodegeneration. The purpose of this work was to delineate noradrenergic neurons in vivo by T 1 -weighted MRI with magnetization transfer (MT). In the brainstem of human and mice, MRI identified the locus coeruleus, dorsal motor vagus nucleus, and nucleus tractus solitarius. Given (1) the long T 1 and low magnetization transfer ratio for the noradrenergic cell groups compared to other gray matter, (2) significant correlation between MT MRI signal intensity and proton density, and (3) no correlation between magnetization transfer ratio (or R 1 ) and iron, copper, or manganese in human brain, the high MRI signal of the noradrenergic neurons must be attributed to abundant water protons interacting with any T 1 -shortening paramagnetic ions in active cells rather than to specific T 1 -shortening molecules. The absence of a high MRI signal from the locus coeruleus of Ear2(−/−) mice lacking noradrenergic neurons confirms that cell bodies of noradrenergic neurons are the source of the bright MRI appearance. The observation of this high signal in DBH(−/−) mice, in 3-week-old mice, and in mice under hyperoxia/hypercapnia/hypoxia together with the general absence of neuromelanin (NM) in noradrenergic neurons of young rodents further excludes that it is due to NM, dopamine β-hydroxylase, their binding to paramagnetic ions, blood inflow, or hemoglobin. Instead, these findings indicate a high density of water protons whose T 1 is shortened by paramagnetic ions as the relevant source of the high MRI signal. In the brain of APP/PS1/Ear2(−/−) mice, a transgenic model of Alzheimer’s disease, MRI detected noradrenergic neuron loss in the locus coeruleus. Proton magnetic resonance spectroscopy revealed that a 60–75% reduction of noradrenaline is responsible for a reduction of N -acetylaspartate and glutamate in the hippocampus as well as for a shortening of the water proton T 2 in the frontal cortex. These results suggest that a concurrent shortage of noradrenaline in Alzheimer’s disease accelerates pathologic processes such as inflammation and neuron loss. Electronic supplementary material The online version of this article (10.1007/s00429-019-01858-0) contains supplementary material, which is available to authorized users.
Quantitative parameter mapping in MRI is typically performed as a two-step procedure where serial imaging is followed by pixelwise model fitting. In contrast, model-based reconstructions directly reconstruct parameter maps from raw data without explicit image reconstruction. Here, we propose a method that determines T1 maps directly from multi-channel raw data as obtained by a single-shot inversion-recovery radial FLASH acquisition with a Golden Angle view order. Joint reconstruction of a T1, spin-density and flip-angle map is formulated as a nonlinear inverse problem and solved by the iteratively regularized Gauss-Newton method. Coil sensitivity profiles are determined from the same data in a preparatory step of the reconstruction. Validations included numerical simulations, in vitro MRI studies of an experimental T1 phantom, and in vivo studies of brain and abdomen of healthy subjects at a field strength of 3 T. The results obtained for a numerical and experimental phantom demonstrated excellent accuracy and precision of model-based T1 mapping. In vivo studies allowed for high-resolution T1 mapping of human brain (0.5-0.75 mm in-plane, 4 mm section thickness) and liver (1.0 mm, 5 mm section) within 3.6-5 s. In conclusion, the proposed method for model-based T1 mapping may become an alternative to two-step techniques, which rely on model fitting after serial image reconstruction. More extensive clinical trials now require accelerated computation and online implementation of the algorithm.
Objective:To develop a novel method for rapid myocardial T1 mapping at high spatial resolution.Methods:The proposed strategy represents a single-shot inversion recovery experiment triggered to early diastole during a brief breath-hold. The measurement combines an adiabatic inversion pulse with a real-time readout by highly undersampled radial FLASH, iterative image reconstruction and T1 fitting with automatic deletion of systolic frames. The method was implemented on a 3-T MRI system using a graphics processing unit-equipped bypass computer for online application. Validations employed a T1 reference phantom including analyses at simulated heart rates from 40 to 100 beats per minute. In vivo applications involved myocardial T1 mapping in short-axis views of healthy young volunteers.Results:At 1-mm in-plane resolution and 6-mm section thickness, the inversion recovery measurement could be shortened to 3 s without compromising T1 quantitation. Phantom studies demonstrated T1 accuracy and high precision for values ranging from 300 to 1500 ms and up to a heart rate of 100 beats per minute. Similar results were obtained in vivo yielding septal T1 values of 1246 ± 24 ms (base), 1256 ± 33 ms (mid-ventricular) and 1288 ± 30 ms (apex), respectively (mean ± standard deviation, n = 6).Conclusion:Diastolic myocardial T1 mapping with use of single-shot inversion recovery FLASH offers high spatial resolution, T1 accuracy and precision, and practical robustness and speed.Advances in knowledge:The proposed method will be beneficial for clinical applications relying on native and post-contrast T1 quantitation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.