Detection and localization of partial discharge are very important in condition monitoring of power cables, so it is necessary to build an accurate recognizer to recognize the discharge types. In this paper, firstly, a power cable model based on FDTD simulation is built to get the typical discharge signals as training samples. Secondly, because the extraction of discharge signal features is crucial, fractal characteristics of the training samples are extracted and inputted into the recognizer. To make the results more accurate, multi-SVM recognizer made up of six Support Vector Machines (SVM) is proposed in this paper. The result of the multi-SVM recognizer is determined by the vote of the six SVM. Finally, the BP neural networks and ELM are compared with multi-SVM. The accuracy comparison shows that the multi-SVM recognizer has the best accuracy and stability, and it can recognize the discharge type efficiently.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.