BackgroundTo compare the clinical effectiveness of ultrasound-guided needle release of the transverse carpal ligament (TCL) with and without corticosteroid injection in carpal tunnel syndrome (CTS).MethodsFrom June 2016 to June 2017, 49 CTS patients (50 wrists) were included in this study. Twenty-five wrists were treated with ultrasound-guided needle release of the TCL plus corticosteroid injection (group A), and 25 wrists were treated with single ultrasound-guided needle release of the TCL (group B). The following parameters were assessed and compared including postprocedure results according to relief of symptoms, ultrasound parameters (cross-sectional area of the median nerve at the levels of pisiform, flattening ratio of median nerve at the levels of the hamate bone, and the thicknesses of TCL on the cross-section at the level of the hamate bone), and electrophysiological parameters (distal motor latency and sensory conduction velocity).ResultsGroup A had higher overall excellent and good rate 3 months after the procedure than group B (84 vs 52%, P < 0.05). There were significant differences regarding the above ultrasonic and electrophysiological parameters between the baseline and postprocedure values in both groups (all P < 0.05). There were significant differences regarding the postprocedure values of above ultrasonic and electrophysiological parameters between the two groups (all P < 0.05). No complications such as infection or tendon rupture were noted. No procedures were converted to the open release.ConclusionsBoth techniques are effective in treating CTS. Ultrasound-guided needle release of the TCL with corticosteroid injection had better treatment benefits than single ultrasound-guided needle release of the TCL in treating CTS.
OBJECTIVE: To compare the clinical effectiveness of ultrasound-guided corticosteroid injection with and without needle release of the A1 pulley in treating trigger finger. METHODS: A total of 60 patients with trigger finger were enrolled in this retrospective study. Among them, 30 patients were treated with ultrasound-guided needle release of the A1 pulley with corticosteroid injection (group A) and 30 patients were treated with single ultrasound-guided corticosteroids injection (group B). The following parameters were evaluated including clinical parameters (pain degree, function of joint, finger tendon function, postoperative satisfaction), and ultrasound parameter (thickness of A1 pulley).
RESULTS:The postoperative visual analogue scale (VAS) and Quinnell scores in two groups were significantly lower than that before operation (p < 0.05). The postoperative Quinnell score of group A was significantly lower than that in group B (p < 0.05). The TAM results showed that the postoperative overall excellent and good rate of group A was significantly higher than that in group B (p < 0.05). The postoperative survey showed that more than 80% patients reported satisfaction in the two groups. The ultrasound imaging results showed that the postoperative thickness of A1 pulley in two groups were thinner than that before operation (p < 0.05). There were no adverse effects and complications in the two groups. CONCLUSIONS: Both approaches had treatment benefit in trigger finger. Ultrasound-guided needle release of the A1 pulley with corticosteroid injection had better treatment benefits than single ultrasound-guided corticosteroids injection in improving finger tendon function and joint function.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.