Smart wearable sensors are essential for continuous health-monitoring applications and detection accuracy of symptoms and energy efficiency of processing algorithms are key challenges for such devices. While several machine-learning-based algorithms for the detection of abnormal breath sounds are reported in literature, they are either too computationally expensive to implement into a wearable device or inaccurate in multi-class detection. In this paper, a kernel-like minimum distance classifier (K-MDC) for acoustic signal processing in wearable devices was proposed. The proposed algorithm was tested with data acquired from open-source databases, participants, and hospitals. It was observed that the proposed K-MDC classifier achieves accurate detection in up to 91.23% of cases, and it reaches various detection accuracies with a fewer number of features compared with other classifiers. The proposed algorithm’s low computational complexity and classification effectiveness translate to great potential for implementation in health-monitoring wearable devices.
BackgroundVeno‐venous extracorporeal membrane oxygenation (V‐V ECMO) is a lifesaving support modality for severe respiratory failure, but its resource‐intensive nature led to significant controversy surrounding its use during the COVID‐19 pandemic. We report the performance of several ECMO mortality prediction and severity of illness scores at discriminating survival in a large COVID‐19 V‐V ECMO cohort.MethodsWe validated ECMOnet, PRESET (PREdiction of Survival on ECMO Therapy‐Score), Roch, SOFA (Sequential Organ Failure Assessment), APACHE II (acute physiology and chronic health evaluation), 4C (Coronavirus Clinical Characterisation Consortium), and CURB‐65 (Confusion, Urea nitrogen, Respiratory Rate, Blood Pressure, age >65 years) scores on the ISARIC (International Severe Acute Respiratory and emerging Infection Consortium) database. We report discrimination via Area Under the Receiver Operative Curve (AUROC) and Area under the Precision Recall Curve (AURPC) and calibration via Brier score.ResultsWe included 1147 patients and scores were calculated on patients with sufficient variables. ECMO mortality scores had AUROC (0.58–0.62), AUPRC (0.62–0.74), and Brier score (0.286–0.303). Roch score had the highest accuracy (AUROC 0.62), precision (AUPRC 0.74) yet worst calibration (Brier score of 0.3) despite being calculated on the fewest patients (144). Severity of illness scores had AUROC (0.52–0.57), AURPC (0.59–0.64), and Brier Score (0.265–0.471). APACHE II had the highest accuracy (AUROC 0.58), precision (AUPRC 0.64), and best calibration (Brier score 0.26).ConclusionWithin a large international multicenter COVID‐19 cohort, the evaluated ECMO mortality prediction and severity of illness scores demonstrated inconsistent discrimination and calibration highlighting the need for better clinically applicable decision support tools.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.