It is now recognized that many large wind farms will employ doubly fed induction generator (DFIG) variable speed wind turbines. A number of such wind farms are already in operation and more are planned or under construction. With the rising penetration of wind power into electricity networks, increasingly comprehensive studies are required to identify the interaction between the wind farm(s) and the power system. These require accurate models of doubly fed induction generator wind turbines and their associated control and protection circuits. A dynamic model has been derived, which can be used to simulate the DFIG wind turbine using a single-cage and double-cage representation of the generator rotor, as well as a representation of its control and protection circuits. The model is suitable for use in transient stability programs that can be used to investigate large power systems. The behavior of a wind farm and the network under various system disturbances was studied using this dynamic model. The influence of the DFIG control on the stability of the wind farm was also investigated by considering different control gains and by applying network voltage control through both stator side and rotor side converters.
Diffraction enhanced imaging (DEI) is a new, synchrotron-based, x-ray radiography method that uses monochromatic, fan-shaped beams, with an analyser crystal positioned between the subject and the detector. The analyser allows the detection of only those x-rays transmitted by the subject that fall into the acceptance angle (central part of the rocking curve) of the monochromator/analyser system. As shown by Chapman et al, in addition to the x-ray attenuation, the method provides information on the out-of-plane angular deviation of x-rays. New images result in which the image contrast depends on the x-ray index of refraction and on the yield of small-angle scattering, respectively. We implemented DEI in the tomography mode at the National Synchrotron Light Source using 22 keV x-rays, and imaged a cylindrical acrylic phantom that included oil-filled, slanted channels. The resulting 'refraction CT image' shows the pure image of the out-of-plane gradient of the x-ray index of refraction. No image artefacts were present, indicating that the CT projection data were a consistent set. The 'refraction CT image' signal is linear with the gradient of the refractive index, and its value is equal to that expected. The method, at the energy used or higher, has the potential for use in clinical radiography and in industry.
We explored the potential for clinical research of computed tomography (CT) with monochromatic x-rays using the preclinical multiple energy computed tomography (MECT) system at the National Synchrotron Light Source. MECT has a fixed, horizontal fan beam with a subject apparatus rotating about a vertical axis; it will be used for imaging the human head and neck. Two CdWO4-photodiode array detectors with different spatial resolutions were used. A 10.5 cm diameter acrylic phantom was imaged with MECT at 43 keV and with a conventional CT (CCT) at 80 kVp: spatial resolution approximately equal to 6.5 line pairs (lp)/cm for both; slice height, 2.6 mm for MECT against 3.0 mm for CCT; surface dose, 3.1 cGy for MECT against 2.0 cGy for CCT. The resultant image noise was 1.5 HU for MECT against 3 HU for CCT. Computer simulations of the same images with more precisely matched spatial resolution, slice height and dose indicated an image-noise ratio of 1.4:1.0 for CCT against MECT. A 13.5 cm diameter acrylic phantom imaged with MECT at approximately 0.1 keV above the iodine K edge and with CCT showed, for a 240 micrograms I ml-1 solution, an image contrast of 26 HU for MECT and 13 and 9 HU for the 80 and 100 kVp CCT, respectively. The corresponding numbers from computer simulation of the same images were 26, 12, and 9 HU, respectively. MECT's potential for use in clinical research is discussed.
Recently there has been significant interest in dual energy CT imaging with several acquisition methods being actively pursued. Here we investigate fast kVp switching where the kVp alternates between low and high kVp every view. Fast kVp switching enables fine temporal registration, helical and axial acquisitions, and full field of view. It also presents several processing challenges. The rise and fall of the kVp, which occurs during the view integration period, is not instantaneous and complicates the measurement of the effective spectrum for low and high kVp views. Further, if the detector digital acquisition system (DAS) and generator clocks are not fully synchronous, jitter is introduced in the kVp waveform relative to the view period.In this paper we develop a method for estimation of the resulting spectrum for low and high kVp views. The method utilizes static kVp acquisitions of air with a small bowtie filter as a basis set. A fast kVp acquisition of air with a small bowtie filter is performed and the effective kVp is estimated as a linear combination of the basis vectors. The effectiveness of this method is demonstrated through the reconstruction of a water phantom acquired with a fast kVp acquisition. The impact of jitter due to the generator and detector DAS clocks is explored via simulation. The error is measured relative to spectrum variation and material decomposition accuracy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.