In order to investigate the effects of stress concentration on low cycle fatigue properties and fracture behaviour of a nickel‐based powder metallurgy superalloy, FGH97, at elevated temperature, the low cycle fatigue tests have been conducted with semi‐circular and semi‐elliptical single‐edge notched plate specimens at 550 and 700 °C. The results show that the fatigue life of the notched specimen decreases with the increase of stress concentration factor and the fatigue crack initiation life evidently decreases because of the defect located in the stress concentration zone. Moreover, the plastic deformation induced by notch stress concentration affects the initial crack occurrence zone. The angle α of the crack occurrence zone is within ±10° of notch bisector for semi‐circular notched specimens and ±20° for semi‐elliptical notched specimens. The crack propagation rate decreases to a minimum at a certain length, D, and then increases with the growth of the crack. The crack propagation rate of the semi‐elliptical notched specimen decelerates at a faster rate than that of the semi‐circular notched specimen because of the increase of the notch plasticity gradient. The crack length, D, is affected by both the applied load and the notch plasticity gradient. In addition, the fracture mechanism is shown to transition from transgranular to intergranular as temperature increases from 550 to 700 °C, which would accelerate crack propagation and reduce the fatigue life.
Based on the Neuber's rule and Walker equation, a new measurement method considering the influence of mean stress and stress gradient is proposed. A stress gradient factor is defined to correct the traditional Walker equation; thus, it is easy to estimate the life of the structural components only based on the purely elastic finite element analysis. The low‐cycle fatigue experiment was carried out by using the direct aging GH4169 notched specimen with different stress concentration factors under evaluated temperature. The fracture morphology of specimens was analyzed to determine the crack initiation position and the damage mechanism. The data points of the experiment life and the estimation life are correlated well within a three times scatter band. It indicates that the Walker equation corrected by introducing a new kind of measurement of stress gradient is reliable to estimate the notched specimen fatigue life.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.