OBJECTIVE: To determine reference values for fat-free mass index (FFMI) and fat mass index (FMI) in a large Caucasian group of apparently healthy subjects, as a function of age and gender and to develop percentile distribution for these two parameters. DESIGN: Cross-sectional study in which bioelectrical impedance analysis (50 kHz) was measured (using tetrapolar electrodes and cross-validated formulae by dual-energy X-ray absorptiometry in order to calculate FFMI (fat-free mass=height squared) and FMI (fat mass=height squared). SUBJECTS: A total of 5635 apparently healthy adults from a mixed non-randomly selected Caucasian population in Switzerland (2986 men and 2649 women), varying in age from 24 to 98 y. RESULTS: The median FFMI (18 -34 y) were 18.9 kg=m 2 in young males and 15.4 kg=m 2 in young females. No difference with age in males and a modest increase in females were observed. The median FMI was 4.0 kg=m 2 in males and 5.5 kg=m 2 in females. From young to elderly age categories, FMI progressively rose by an average of 55% in males and 62% in females, compared to an increase in body mass index (BMI) of 9 and 19% respectively. CONCLUSIONS: Reference intervals for FFMI and FMI could be of practical value for the clinical evaluation of a deficit in fat-free mass with or without excess fat mass (sarcopenic obesity) for a given age category, complementing the classical concept of body mass index (BMI) in a more qualitative manner. In contrast to BMI, similar reference ranges seems to be utilizable for FFMI with advancing age, in particular in men.
To further validate the doubly labeled water method for measurement of CO2 production and energy expenditure in humans, we compared it with near-continuous respiratory gas exchange in nine healthy young adult males. Subjects were housed in a respiratory chamber for 4 days. Each received 2H2(18)O at either a low (n = 6) or a moderate (n = 3) isotope dose. Low and moderate doses produced initial 2H enrichments of 5 and 10 X 10(-3) atom percent excess, respectively, and initial 18O enrichments of 2 and 2.5 X 10(-2) atom percent excess, respectively. Total body water was calculated from isotope dilution in saliva collected at 4 and 5 h after the dose. CO2 production was calculated by the two-point method using the isotopic enrichments of urines collected just before each subject entered and left the chamber. Isotope enrichments relative to predose samples were measured by isotope ratio mass spectrometry. At low isotope dose, doubly labeled water overestimated average daily energy expenditure by 8 +/- 9% (SD) (range -7 to 22%). At moderate dose the difference was reduced to +4 +/- 5% (range 0-9%). The isotope elimination curves for 2H and 18O from serial urines collected from one of the subjects showed expected diurnal variations but were otherwise quite smooth. The overestimate may be due to approximations in the corrections for isotope fractionation and isotope dilution. An alternative approach to the corrections is presented that reduces the overestimate to 1%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.