Objective: We propose a modified conformity index (MCI), based on extended volume, that improves on existing indices by correcting for the insensitivity of previous conformity indices to reference dose shape to assess the quality of high-precision radiation therapy and present an evaluation of its application. Methods: In this paper, the MCI is similar to the conformity index suggested by Paddick (CI Paddick ), but with a different correction factor. It is shown for three cases: with an extended target volume, with an extended reference dose volume and without an extended volume. Extended volume is generated by expanding the original volume by 0.1-1.1 cm isotropically. Focusing on the simulation model, measurements of MCI employ a sphere target and three types of reference doses: a sphere, an ellipsoid and a cube. We can constrain the potential advantage of the new index by comparing MCI with CI Paddick . The measurements of MCI in head-neck cancers treated with intensity-modulated radiation therapy and volumetric-modulated arc therapy provide a window on its clinical practice.Results: The results of MCI for a simulation model and clinical practice are presented and the measurements are corrected for limited spatial resolution. The three types of MCI agree with each other, and comparisons between the MCI and CI Paddick are also provided. Conclusion:The results from our analysis show that the proposed MCI can provide more objective and accurate conformity measurement for high-precision radiation therapy. In combination with a dose-volume histogram, it will be a more useful conformity index.
Purpose: To investigate the accuracy of volume measurements in phantoms with known volumes calculated by four radiation therapy treatment‐planning systems from routine‐clinic CT images and evaluate their overall performances. The methodology to improve the accuracy is proposed. Method and Materials: An ellipsoid mammosite was used as a phantom injected with 35, 45, 55, and 65cc of saline separately, and scanned by a multi‐detector CT (GE, 4‐Slice helical Scan, 1.25mm thickness, 512×512). The images were transferred to 4 treatment‐planning systems: GE simulation workstation, ADAC Pinnacle, BrainLab and Varian VariSeed. Image windows & levels were adjusted to see the wall of the phantom and kept same in each system. ROIs of the phantom and central catheter were segmented in CT slices by automatic contour tool (unavailable in VarianSeed, manually contoured by a physicist). The total volume of each phantom was generated from 3D ROI stack by volume‐calculating toolkits. The actual saline volume in each phantom was calculated by subtracting the catheter volume from the total phantom volume. To approach the true injected volume, dilation or erosion of phantom's ROIs was performed. Results: The average measured and the true volumes varied by −9.86%, −10.24%, −11.748%, −13.02% for the GE, Pinnacle, BrainLab, and VariSeed systems respectively. For 35cc phantom, if phantom ROIs were dilated by two pixels, the measured volume was approaching its true value. The difference between average measured and the true volumes decreased from −11.74% to −10.15 when phantom volumes increased from 35cc to 65cc Conclusions: Image windows & levels have the greatest impact on calculating accurate volumes. All planning systems underestimated the true volume of the phantoms by about 11%. This underestimation should be factored in the clinical settings when calculating Dose Volume Histograms especially for IMRT plans. Furthermore, two‐pixel dilation could fill the gap between measurements and true volumes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.