Summary Introduction Activated partial thromboplastin time (aPTT) is a routine clotting assay that is widely used to globally screen for coagulation abnormalities. It is commonly admitted that a prolonged test result, may trigger the need for specific assays to be performed, particularly factor measurement. However, the sensitivity of aPTT reagents to deficiencies of clotting factors varies. Methods We evaluated, according to the recommendation of the CLSI H47‐A2 guideline, the responsiveness to single factor levels of five aPTT reagents by using factor‐deficient plasmas spiked with a calibration plasma to produce individual factor activities ranging from <1 to ~100 Unit (U)/dL. Test results were expressed as the sample‐to‐control ratio, the latter was defined as the clotting time obtained in the calibration plasma containing ~100 U/dL factor activity. The factor activity producing a prolongation of aPTT above the upper limit of its specific normal range (in ratio) was assigned as the factor responsiveness in U/dL to that reagent. Results Responsiveness ranged from 34 to 47 U/dL to FVIII:C, from 18 to 57 U/dL to FIX, from 38 to 52 U/dL to FXI, from 29 to 50 U/dL to FXII, from 40 and 59 U/dL to FV, from 7.5 to 49 U/dL to FX, and from 9.1 to 10.5 U/dL to FII. Conclusions These results suggest that the sensitivity of the tested aPTT reagents to single factor deficiency is highly variable. Moreover, for one given aPTT reagent, its sensitivity was very different depending on the deficient factor. This must be considered when analyzing clinical materials.
Activated partial thromboplastin time (aPTT) is a routine clotting assay that is widely used to globally screen for coagulation abnormalities, particularly in the pre-operative period. It is commonly admitted that a prolonged test result, may trigger the need for specific assays to be performed and particularly factor assay. However, the responsiveness of aPTT reagents to deficiencies of clotting factors varies because of differences in the type of activator and in the composition/concentration in phospholipids. To investigate the suitability of 5 commercially available aPTT reagents to detect mild/moderate deficiencies of clotting factors, we assessed their responsiveness at increasing concentrations of factors involved not only in the intrinsic pathway of the coagulation system, but also in the common pathway, as very few data were available. The sensitivity of 5 aPTT reagents i.e. HemosIL APTT SP (Instrumentation Laboratory, IL), HemosIL SynthASil (IL), STA-CK Prest (Stago), TriniCLOT aPTT HS (TCoag), and TriniCLOT Automated aPTT (TCoag) to clotting factor was assessed according to the recommendation of the CLSI H47-A2 guideline, by using factor-deficient plasmas spiked with a calibration plasma (all from IL) to produce individual FVIII:C, FIX, FXI, FXII, FV, FX, or FII activities ranging from <1% to ~100 %. Each of the spiked plasma samples was used for the determination of aPTT after being assayed to confirm the activity of the single factor. Tests were simultaneously performed in duplicate on the ACL TOP 700 analyzer (IL) and the values were averaged. Test results were expressed as the sample-to-control ratio, the latter was defined as the clotting time obtained in the calibration plasma containing ~100 % factor activity. The factor activity producing a prolongation of aPTT above 1.20 (patient-to-control ratio) was assigned as the factor responsiveness in % for that reagent. The level (in %) of a given clotting factor responsible for the prolongation of aPTT above 1.20 was highly variable from one aPTT reagent to another (Table). Moreover, for one given aPTT reagent, its sensitivity was very different depending on the specific factor. Actually, the aPTT responsiveness to FVIII:C ranged from 33 % with TriniCLOT aPTT HS to 46 % with HemosIL APTT SP. For FIX, the range was from 18 % with TriniCLOT Automated aPTT to 57 % with HemosIL SynthASil. The aPTT responsiveness to FXI ranged from 38 % with HemosIL SynthASil to 50 % with HemosIL APTT SP, and that to FXII was from 27 % with STA-CK Prest to 48 % with TriniCLOT aPTT HS. So, HemosIL APTT SP showed a good sensitivity (above 42%) to all 3 clotting factors which mild deficiencies are known to be associated with an hemorrhagic tendency (FVIII:C, FIX, and FXI). The same applied to HemosIL SynthASil, which was very sensitive to FIX deficiency (57%), and to STA-CK Prest and TriniCLOT aPTT HS with borderline sensitivity to FIX (29 % for both). The responsiveness to FIX of TriniCLOT Automated APTT was found to be very low (18%). Concerning coagulation factors involved in the common coagulation pathway, the sensitivity to FV was between 38 % with STA-CK Prest and 61 % with TriniCLOT Automated aPTT and that to FX was between 7.0 % with TriniCLOT aPTT HS and 49 % with HemosIL SynthASil. The sensitivity to FII was very low and quite similar for the 5 tested reagents in the range from 9.1 % to 10.7 %. Table. HemosIL APTT SP HemosIL SynthASil STA-CK Prest TriniCLOT APTT HS TriniCLOT Automated aPTT Factor VIII (%) 46 38 43 33 41 Factor IX (%) 42 57 29 29 18 Factor XI (%) 50 38 44 48 46 Factor XII (%) 31 42 27 48 41 Factor V (%) 45 44 38 44 61 Factor X (%) 17 49 16 7.0 9.2 Factor II (%) 9.7 9.1 10.0 9.5 10.7 The difference between reagents responsiveness to FIX was confirmed using plasma samples from patients with hemophilia B either treated with FIX concentrates or not. These results suggested that the sensitivity of the 5 tested aPTT reagents to single factor deficiency was highly variable. If the responsiveness to FVIII:C and FXI of the tested aPTT reagents was accurate, it was not the case for FIX with borderline sensitivity of STA-CK Prest and TriniCLOT aPTT HS (29 %), and more importantly a too low sensitivity of Triniclot Automated aPTT (18%). As this was confirm in clinical materials, this must be considered when analyzing clinical materials, particularly plasma from hemophilia B patients, as mild deficiency states might be undiagnosed with the less sensitive reagent. Disclosures No relevant conflicts of interest to declare.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.