In daily life and sports activities, the knee joint is the dominant joint. Movements such as walking upstairs, running, and walking require the knee joint to function. The principle of tissue engineering and the technical methods of molecular biology to construct functional meniscus replacement products in vitro have become an ideal method to fundamentally solve the meniscus injury. This paper aims to study the application of tissue engineered nanomaterials in meniscal sports injury repair. In this paper, KOA exercise therapy based on Kalman filter theory is proposed, which has a great effect on the rehabilitation of bone tissue injuries. The experimental results of this paper show that in the number of people with meniscus injuries in 2013, the percentage of people younger than 25 years old was 13%, and the percentage of people younger than 25 years old in 2020 was 12%, which did not change much. However, the percentage of people over 40 years old was 57% in 2013, and by 2020, the percentage is 66%. Although the increase is not large, the percentage of people over the age of 40 is the highest every year, which means that older people have a higher proportion of meniscal injuries.
As an important part of the human body, skeletal muscle is easily damaged in the process of exercise. The purpose of this study is to investigate the controllable construction and biocompatibility of biomimetic calcium carbonate nanocomposites in exercise skeletal muscle repair. In this study, adult healthy mice were selected as the research objects. First, the mice were anesthetized with 2.5% pentobarbital sodium. Then, the mice were fixed and hit with steel balls on the middle part of the gastrocnemius muscle abdomen to establish a skeletal muscle contusion model. The mice were killed by cervical dislocation under anesthesia. The injured gastrocnemius muscles were quickly removed to prepare the cell suspension. 0.8600 g chitosan was weighed and dissolved in 200 ml deionized water. Then, 0.0660 g of calcium chloride dihydrate was added and stirred to dissolve to prepare chitosan calcium carbonate composite. The calcium carbonate composite material with a length of 8.0 cm is cut into a square sheet of stainless steel. The stainless steel plate was sterilized and then placed in a 12 culture plate to dilute the full cells in the culture bottle. The cells were seeded in 12 well culture plates, and 100 μL cells and 600 μL medium were added to each well. The samples were cultured in the incubator (there were three control holes in each group for SEM test, three control holes for fluorescence measurement, and six control holes for MTT measurement). The plates were taken out and placed in a new 24 plate. 1000 μL medium was added. Then. 100 μL MTT solution was added into each well. The biocompatibility test was conducted for 4 h. The GSH PX level in the chitosan calcium carbonate composite group was lower than that in the natural recovery group ( P < 0.01 ). The results showed that chitosan calcium carbonate composite could promote the growth of skeletal muscle cells.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.