A novel modified version of the Wells-Riley model was used to estimate the impact of relative humidity (RH) on the removal of respiratory droplets containing the SARS-CoV-2 virus by deposition through gravitational settling and its inactivation by biological decay; the effect of RH on susceptibility to SARS-CoV-2 was not considered. These effects were compared with the removal achieved by increased ventilation rate with outdoor air. Modeling was performed assuming that the infected person talked continuously for 60 and 120 min. The results of modeling showed that the relative impact of RH on the infection risk depended on the ventilation rate and the size range of virus-laden droplets. A ventilation rate of 0.5 ACH, the change of RH between 20% and 53% was predicted to have a small effect on the infection risk, while at a ventilation rate of 6 ACH this change had nearly no effect. On the contrary, increasing the ventilation rate from 0.5 ACH to 6 ACH was predicted to decrease the infection risk by half which is remarkably larger effect compared with that predicted for RH. It is thus concluded that increasing the ventilation rate is more beneficial for reducing the airborne levels of SARS-CoV-2 than changing indoor RH.
Practical implications
The present results show that humidification to moderate levels of 40%–60% RH should not be expected to provide a significant reduction in infection risk caused by SARS-CoV-2, hence installing and running humidifiers may not be an efficient solution to reduce the risk of COVID-19 disease in indoor spaces. The results do however confirm that ventilation has a key role in controlling SARS-CoV-2 virus concentration in the air providing considerably higher benefits. The modified model developed in the present work can be used by public health experts, engineers, and epidemiologists when selecting different measures to reduce the infection risk from SARS-CoV-2 indoors allowing informed decisions concerning indoor environmental control.
Predicting influence of human thermal plume on the diffusion of respiration-produced particles is an important issue for improving indoor air quality through eliminating infectious microbes efficiently. In this study, the Large Eddy Simulation was utilized to predict the effects of thermal plume of different intensities on particle diffusion. Three postures of the human body model and three room temperatures were considered. The results show that the convective heat transfer coefficient on the surface of the human body varies greatly with different postures. The coefficient is the largest when the model is in sitting posture, leading to the greatest heat transfer rate. Meanwhile, the thermal plume generated by bending the thigh increases the size of the facial thermal plume in horizon direction. The increase of the difference between indoor temperature and skin temperature causes an increase of the convective heat transfer of the manikin, leading to stronger airflow in front of the face. The thicker and faster the human thermal plume is, the more difficult it is penetrated by aerosols produced by nasal breathing, finally resulting in most particles distributed within 0.2 m thick under the roof.
The interference fit can improve the fatigue performance of mechanical joints and is widely used in aircraft assembly. In this paper, specimens of lap plates and several interference fit sizes were designed, and then the interference fit hi-lock bolt insertion was carried out in an experimental test. Using the commercial finite element software ABAQUS, a two-dimensional axisymmetric finite element model was established to simulate the bolt insertion process. The finite element model was validated by comparison of experimental results and finite element prediction for insertion force and protuberance height. After the interference fitted bolt insertion, the changing characteristics of the non-uniform hole expansion and protuberance were presented with increases in interference fit size. Under low level of interference fit, the tensile hoop stress was produced mainly on the hole wall, and changed into compressive hoop stress when interference fit size is larger. The maximum tensile hoop stress point on faying surfaces went away from the hole wall with interference fit size increasing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.