A single-screw expander has been designed and manufactured independently. Based on this prototype, testing system has been built and performance experiment has been made. In this article, compressed air was used as working fluid and performance test for the prototype was finished at conditions including different rotational speed and different inlet pressure.From the experimental data, it is shown that when inlet pressure less than 0.8MPa the output power increases with the increase of rotational speed because of not enough expansion; when inlet pressure more than 0.8MPa, the every biggest output power is appeared in the condition of rotational speed 2600 rpm. The test results also show that the total efficiency is influenced by rotational speed obviously, and the highest total efficiency of this machine is 69.64% in the condition of 3000 rpm and 15 bar.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.