Hemoglobin based oxygen-carrying solutions (HBOCs) as hemoglobin replacement therapeutics are being tested for clinical use. Some of these products are associated with elevations in both systemic and pulmonary vascular resistances but their effect on the distribution of blood flow to major organs in larger animals have not been extensively described. We tested two formulations of o-raffinose cross-linked human hemoglobin, Hemolink (frozen Hemolink-1 and refrigerated Hemolink-2) and compared them to Pentaspan, a colloid volume expander in extensive clinical use. Cardiovascular measurements and the distribution of blood flow (radionuclide-labeled microspheres) to the major organs were determined in Beagle dogs (n=5 per group). After baseline measurements, either Hemolink-1, or Hemolink-2, or Pentaspan was exchange transfused in an isovolemic manner (resulting in hematocrit reduction to approximately 20-25%); measurements were made 30, 60, 120 and 180 min post-exchange. There was no significant difference in cardiac output, mean arterial pressures and systemic or pulmonary vascular resistance after exchange in any of the three groups. Myocardial blood flow increased in all three groups post-exchange but the increase was more sustained in the Hemolink groups. Endocardial/epicardial flow ratios were also maintained after exchange in all groups. Thus, Hemolink is ideally suited for volume replacement when used in conjunction with acute normovolemic hemodilution because under these circumstances, the adverse hemodynamic effects are alleviated while extra hemoglobin is added to the blood.
Hemoglobin based oxygen-carrying solutions (HBOCs) as hemoglobin replacement therapeutics are being tested for clinical use. Some of these products are associated with elevations in both systemic and pulmonary vascular resistances but their effect on the distribution of blood flow to major organs in larger animals have not been extensively described. We tested two formulations of o-raffinose cross-linked human hemoglobin, Hemolink (frozen-Hemolink-1 and refrigerated Hemolink-2) and compared them to Pentaspan, a colloid volume expander in extensive clinical use. Cardiovascular measurements and the distribution of blood flow (radionuclide-labeled microspheres) to the major organs were determined in Beagle dogs (n = 5 per group). After baseline measurements, either Hemolink-1, Hemolink-2, or Pentaspan was exchange transfused in an isovolemic manner (resulting in hematocrit reduction to approximately 20-25%); measurements were made 30, 60, 120 and 180 min post-exchange. There was no significant difference in cardiac output, mean arterial pressures and systemic or pulmonary vascular resistances after exchange in any of the three groups. Myocardial blood flow increased in all three groups post-exchange but the increase was more sustained in the Hemolink groups. Endocardial/epicardial flow ratios were also maintained after exchange in all groups. Thus, Hemolink is ideally suited for volume replacement when used in conjunction with acute normovolemic hemodilution because under these circumstances, the adverse hemodynamic effects are alleviated while extra hemoglobin is added to the blood.
Chronic osteomyelitis in presence of orthopedic implants is a condition observed in the field of biomaterials as it impairs early bone-implant contact, fixation and integration. In this study, a surgical intramedullary tibial insertion was performed using a titanium wire previously inoculated with Staphylococcus aureus in order to develop an osteomyelitis model in a clinically relevant long bone and in absence of any prophylactic treatment. As such, twenty-two male Sprague-Dawley rats received a sterile or inoculated intramedullary biomaterial with either 2 × 10 6 or 1 × 10 7 S. aureus colony forming units. Bacterial burden, inflammation, morphological changes, as well as newly formed bone tissues were evaluated for histopathology following a period of either eight or fifteen days of implantation. The implant inoculated in presence of the highest bacterial load was effective to produce significant periprosthetic infection observations in addition to hard and soft tissue inflammation consistent with the development of osteomyelitis. In contrast, neither the sterile nor the low-dose implant inoculation showed inflammation and clinical infection signs, but rather produced an expected bone remodeling and appropriate healing associated with biomaterial implantation. Complete health assessment is presented with histopathological periprosthetic results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.