We investigate the dynamical behavior of oscillatory electrodissolution of two nickel microwires in an on-chip integrated microfluidic flow cell. With equivalent circuit analysis, an equation is derived that shows that the electrical coupling strength between the electrodes can be intensified by increasing the distance from the downstream electrode to the reference/counter electrodes, increasing the electrode size, and decreasing the total resistance within the cell. Experiments and numerical simulations with an ordinary differential equation model show that by intensifying the coupling between the electrodes spontaneously synchronized oscillations occur due to large potential (IR) drop in the small flow channel. Experiments with different distances, electrode diameters, and total resistances confirm a correlation between the statistical entropy based synchrony index and the theoretically derived coupling strength formula. The findings thus show that dynamical features of the chemical reaction that have been previously seen with macroelectrodes with application of external coupling resistances can occur spontaneously with microwires. The delineation of coupling effects in the reaction system could facilitate kinetic and electroanalytical applications in design of microchip-based setups that require collector-generator multielectrode wires: the accuracy of the measurement can be improved by proper cell design that diminishes electrical cross talk.
ObjectiveExcessive carbohydrate intake is a high risk factor for increased morbidity of type 2 diabetes (T2D). A novel regimen for the dietary care of diabetes that consists of a highly active α-amylase inhibitor derived from white common bean extract (WCBE) and sufficient carbohydrates intake was applied to attenuate T2D and its complications. Furthermore, the role of gut microbiota in this remission was also investigated.MethodsWe conducted a 4-month randomized double-blinded placebo-controlled trial. During the intense intervention period, ninety subjects were randomly assigned to the control group (Group C) and WCBE group (Group W). Subjects in Group C were supplemented with 1.5 g of maltodextrin as a placebo. Subjects in Group W took 1.5 g of WCBE half an hour before a meal. Fifty-five participants continued the maintenance intervention receiving the previous dietary intervention whereas less frequent follow-up. The variation in biochemical, vasculopathy and neuropathy indicators and the structure of the fecal microbiota during the intervention was analyzed.ResultGlucose metabolism and diabetic complications showed superior remission in Group W with a 0.721 ± 0.742% decline of glycosylated hemoglobin after 4 months. The proportion of patients with diabetic peripheral neuropathy (Toronto Clinical Scoring System, TCSS ≥ 6) was significantly lower in Group W than in Group C. Both the left and right sural sensory nerve conduction velocity (SNCV-left sural and SNCV-right sural) slightly decreased in Group C and slightly increased in Group W. Additionally, the abundances of Bifidobacterium, Faecalibacterium and Anaerostipes were higher in Group W, and the abundances of Weissella, Klebsiella, Cronobacter and Enterobacteriaceae_unclassified were lower than those in Group C at month 2. At the end of month 4, Bifidobacterium remained more abundant in Group W.ConclusionTo our knowledge, this is the first report of improvement to diabetes complications by using a dietary supplement in such a short-term period. The enrichment of SCFA-producing bacteria might be responsible for the attenuation of T2D and its complications.Clinical trial registration numberhttp://www.chictr.org.cn/edit.aspx?pid=23309&htm=4, identifier ChiCTR-IOR-17013656
The formation of spatiotemporal patterns is investigated by using a chemical reaction on the surface of a high-aspect-ratio metal electrode positioned in a flow channel. A partial differential equation model is formulated for nickel dissolution in sulfuric acid in a microfluidic flow channel. The model simulations predict oscillatory patterns that are spatially distributed on the electrode surface; the downstream portion of the metal surface exhibits large-amplitude, nonlinear oscillations of dissolution rates, whereas the upstream portion displays small-amplitude, harmonic oscillations with a phase delay. The features of the dynamical response can be interpreted by the dependence of local dynamics on the widely varying surface conditions and the presence of strong coupling. The patterns can be observed for both contiguous and segmented metal surfaces. The existence of spatially distributed current oscillations is confirmed in experiments with Ni electrodissolution in a microfluidic device. The results show the impact of a widely heterogeneous environment on the types of patterns of chemical reaction rates.
The analysis of network interactions among dynamical units and the impact of the coupling on self-organized structures is a challenging task with implications in many biological and engineered systems. We explore the coupling topology that arises through the potential drops in a flow channel in a lab-on-chip device that accommodates chemical reactions on electrode arrays. The networks are revealed by analysis of the synchronization patterns with the use of an oscillatory chemical reaction (nickel electrodissolution) and are further confirmed by direct decoding using phase model analysis. In dual electrode configuration, a variety coupling schemes, (uni- or bidirectional positive or negative) were identified depending on the relative placement of the reference and counter electrodes (e.g., placed at the same or the opposite ends of the flow channel). With three electrodes, the network consists of a superposition of a localized (upstream) and global (all-to-all) coupling. With six electrodes, the unique, position dependent coupling topology resulted spatially organized partial synchronization such that there was a synchrony gradient along the quasi-one-dimensional spatial coordinate. The networked, electrode potential (current) spike generating electrochemical reactions hold potential for construction of an in-situ information processing unit to be used in electrochemical devices in sensors and batteries.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.