This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). The Grading of Recommendations Assessment, Development, and Evaluation (GRADE) system was adopted to define the strength of recommendations and the quality of evidence. Main recommendations: The following recommendations for post-polypectomy endoscopic surveillance should be applied only after a high quality baseline colonoscopy with complete removal of all detected neoplastic lesions. 1 In the low risk group (patients with 1???2 tubular adenomas?10?mm with low grade dysplasia), the ESGE recommends participation in existing national screening programmes 10 years after the index colonoscopy. If no screening programme is available, repetition of colonoscopy 10 years after the index colonoscopy is recommended (strong recommendation, moderate quality evidence). 2 In the high risk group (patients with adenomas with villous histology or high grade dysplasia or ?10?mm in size, or ??3 adenomas), the ESGE recommends surveillance colonoscopy 3 years after the index colonoscopy (strong recommendation, moderate quality evidence). Patients with 10 or more adenomas should be referred for genetic counselling (strong recommendation, moderate quality evidence). 3 In the high risk group, if no high risk adenomas are detected at the first surveillance examination, the ESGE suggests a 5-year interval before a second surveillance colonoscopy (weak recommendation, low quality evidence). If high risk adenomas are detected at first or subsequent surveillance examinations, a 3-year repetition of surveillance colonoscopy is recommended (strong recommendation, low quality evidence). 4 The ESGE recommends that patients with serrated polyps 10?mm in size with no dysplasia should be classified as low risk (weak recommendation, low quality evidence). The ESGE suggests that patients with large serrated polyps (??10?mm) or those with dysplasia should be classified as high risk (weak recommendation, low quality evidence). 5 The ESGE recommends that the endoscopist is responsible for providing a written recommendation for the post-polypectomy surveillance schedule (strong recommendation, low quality evidence).
Main Recommendations 1 ESGE suggests that high definition endoscopy, and dye or virtual chromoendoscopy, as well as add-on devices, can be used in average risk patients to increase the endoscopist’s adenoma detection rate. However, their routine use must be balanced against costs and practical considerations.Weak recommendation, high quality evidence. 2 ESGE recommends the routine use of high definition systems in individuals with Lynch syndrome.Strong recommendation, high quality evidence. 3 ESGE recommends the routine use, with targeted biopsies, of dye-based pancolonic chromoendoscopy or virtual chromoendoscopy for neoplasia surveillance in patients with long-standing colitis.Strong recommendation, moderate quality evidence. 4 ESGE suggests that virtual chromoendoscopy and dye-based chromoendoscopy can be used, under strictly controlled conditions, for real-time optical diagnosis of diminutive (≤ 5 mm) colorectal polyps and can replace histopathological diagnosis. The optical diagnosis has to be reported using validated scales, must be adequately photodocumented, and can be performed only by experienced endoscopists who are adequately trained, as defined in the ESGE curriculum, and audited.Weak recommendation, high quality evidence. 5 ESGE recommends the use of high definition white-light endoscopy in combination with (virtual) chromoendoscopy to predict the presence and depth of any submucosal invasion in nonpedunculated colorectal polyps prior to any treatment. Strong recommendation, moderate quality evidence. 6 ESGE recommends the use of virtual or dye-based chromoendoscopy in addition to white-light endoscopy for the detection of residual neoplasia at a piecemeal polypectomy scar site. Strong recommendation, moderate quality evidence. 7 ESGE suggests the possible incorporation of computer-aided diagnosis (detection and characterization of lesions) to colonoscopy, if acceptable and reproducible accuracy for colorectal neoplasia is demonstrated in high quality multicenter in vivo clinical studies. Possible significant risks with implementation, specifically endoscopist deskilling and over-reliance on artificial intelligence, unrepresentative training datasets, and hacking, need to be considered. Weak recommendation, low quality evidence.
Serrated polyps, including SSA/Ps, were frequently encountered in routine screening colonoscopies. Large and proximal hyperplastic polyps, as well large and proximal SSA/Ps, were associated with advanced neoplasia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.