We hypothesized that considerable force reserve exists for the diaphragm muscle (DIAm) to generate transdiaphragmatic pressures (Pdi) necessary to sustain ventilation. In rats, we measured Pdi and DIAm EMG activity during different ventilatory (eupnea and hypoxia (10% O2) – hypercapnia (5% CO2)) and non-ventilatory (airway occlusion and sneezing induced by intranasal capsaicin) behaviors. Compared to maximum Pdi (Pdimax - generated by bilateral phrenic nerve stimulation), the Pdi generated during eupnea (21±2%) and hypoxia-hypercapnia (28±4%) were significantly less (P<0.0001) than that generated during airway occlusion (63±4%) and sneezing (94±5%). The Pdi generated during spontaneous sighs was 62±5% of Pdimax. Relative DIAm EMG activity (root mean square [RMS] amplitude) paralleled the changes in Pdi during different ventilatory and non-ventilatory behaviors (r2=0.78; p<0.0001). These results support our hypothesis of a considerable force reserve for the DIAm to accomplish ventilatory behaviors. A model for DIAm motor unit recruitment predicted that ventilatory behaviors would require activation of only fatigue resistant units.
Phrenic motor neurons are recruited across a range of motor behaviors to generate varying levels of diaphragm muscle (DIAm) force. We hypothesized that DIAm motor units are recruited in a fixed order across a range of motor behaviors of varying force levels, consistent with the Henneman Size Principle. Single motor unit action potentials and compound DIAm EMG activities were recorded in anesthetized, neurally intact rats across different motor behaviors, i.e., eupnea, hypoxia-hypercapnia (10% O2 and 5% CO2), deep breaths, sustained airway occlusion, and sneezing. Central drive [estimated by root-mean-squared (RMS) EMG value 75 ms after the onset of EMG activity (RMS75)], recruitment delay, and onset discharge frequencies were similar during eupnea and hypoxia-hypercapnia. Compared with eupnea, central drive increased (∼25%) during deep breaths, and motor units were recruited ∼12 ms earlier (P < 0.01). During airway occlusion, central drive was ∼3 times greater, motor units were recruited ∼30 ms earlier (P < 0.01), and motor unit onset discharge frequencies were significantly higher (P < 0.01). Recruitment order of motor unit pairs observed during eupnea was maintained for 98%, 87%, and 84% of the same pairs recorded during hypoxia-hypercapnia, deep breaths, and airway occlusion, respectively. Reversals in motor unit recruitment order were observed primarily if motor unit pairs were recruited <20 ms apart. These results are consistent with DIAm motor unit recruitment order being determined primarily by the intrinsic size-dependent electrophysiological properties of phrenic motor neurons.
The diaphragm muscle is main inspiratory muscle in mammals. Quantitative analyses documenting the reliability of chronic diaphragm EMG recordings are lacking. Assessment of ventilatory and non-ventilatory motor behaviors may facilitate evaluating diaphragm EMG activity over time. We hypothesized that normalization of diaphragm EMG amplitude across behaviors provides stable and reliable parameters for longitudinal assessments of diaphragm activity. We found that diaphragm EMG activity shows substantial intra-animal variability over 6 weeks, with coefficient of variation (CV) for different behaviors ~29–42%. Normalization of diaphragm EMG activity to near maximal behaviors (e.g., deep breathing) reduced intra-animal variability over time (CV ~22–29%). Plethysmographic measurements of eupneic ventilation were also stable over 6 weeks (CV ~13% for minute ventilation). Thus, stable and reliable measurements of diaphragm EMG activity can be obtained longitudinally using chronically implanted electrodes by examining multiple motor behaviors. By quantitatively determining the reliability of longitudinal diaphragm EMG analyses, we provide an important tool for evaluating the progression of diseases or injuries that impair ventilation.
The diaphragm muscle (DIAm) is critically responsible for sustaining ventilation. Previously we showed in a commonly used model of spinal cord injury, unilateral spinal cord hemisection at C(2) (SH), that there are minimal changes to muscle fiber cross-sectional area (CSA) and fiber type distribution following 14 days of SH-induced ipsilateral DIAm inactivity. In the present study, effects of long-term SH-induced inactivity on DIAm fiber size and force were examined. We hypothesized that prolonged inactivity would not result in substantial DIAm atrophy or force loss. Adult rats were randomized to control or SH groups (n = 34 total). Chronic bilateral DIAm electromyographic (EMG) activity was monitored during resting breathing. Minimal levels of spontaneous recovery of ipsilateral DIAm EMG activity were evident in 42% of SH rats (<25% of preinjury root mean square amplitude). Following 42 days of SH, DIAm specific force was reduced 39%. There was no difference in CSA for type I or IIa DIAm fibers in SH rats compared with age, weight-matched controls (classification based on myosin heavy chain isoform expression). Type IIx and/or IIb DIAm fibers displayed a modest 20% reduction in CSA (P < 0.05). Overall, there were no differences in the distribution of fiber types or the contribution of each fiber type to the total DIAm CSA. These data indicate that reduced specific force following prolonged inactivity of the DIAm is associated with modest, fiber type selective adaptations in muscle fiber size and fiber type distribution.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.