A capillary electrophoresis method has been developed for the analysis of omethoate and dichlorvos. Response surface methodology (RSM) was used to optimize the separate conditions for simultaneous detection of omethoate and dichlorvos. The results indicated that the optimal conditions for omethoate and dichlorvos determination were; pH 7.64, SDS concentration 67.5 mM, separation voltage 19.0 KV. Quantitative linear ranges were 1.0-300 microg/mL for omethoate and dichlorvos with correlation of 0.9967 and 0.9965, respectively. The limits of detection were 0.046 microg/mL and 0.031 microg/mL for omethoate and dichlorvos, with relative standard deviations (R.S.D.) <3.6%. The value of recoveries for omethoate and dichlorvos were arranged from 94.1% to 106.0%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.