BackgroundThe locking plates are often used for internal fixation of closed tibial fractures. The use of a locking plate as an external fixator is still controversial, particularly for closed fractures. The purpose of this study is to evaluate the results of external fixation using the femoral less invasive stabilization system (LISS) plate in proximal metaphyseal fractures of the tibia.MethodsWe prospectively evaluated 35 patients (26 males and 9 females) with a mean age of 42 years (range, 21 to 62 years) who presented with fresh tibial proximal metaphyseal fractures. According to the AO Foundation and Orthopaedic Trauma Association (AO/OTA) classification, the fractures were identified as type 41-A2 in 18 cases and type 41-A3 in 17 cases, including 25 closed fractures and 10 open fractures. The femoral LISS plate was used to fix these fractures, which was placed on the anteromedial aspect of the tibia as an external fixator. The mean follow-up period was 18 months (range, 13 to 22 months).ResultsAll fractures healed in a mean time of 14 weeks (range, 10 to 20 weeks). There was no case of nonunion, deep infection, and loosening of screws and plates. One month after the appearance of cortical bridging on biplanar radiographs, the locking plate was removed within 3 minutes in the clinic without any difficulty. According to the Hospital for Special Surgery (HSS) knee scoring system and American Orthopaedic Foot & Ankle Society (AOFAS) ankle scoring system, the mean HSS score was 91 (range, 85 to 100) and 98 (range, 93 to 100), and the mean AOFAS score was 94 (range, 90 to 100) and 98 (range, 95 to 100) at 4 weeks postoperatively and final follow-up, respectively.ConclusionsFor proximal metaphyseal fracture of the tibia, external fixation using the femoral LISS plate is a safe and reliable technique with minimal complications and excellent outcomes. Its advantages include ease of performing the surgery, use of a less invasive technique, and convenience of plate removal after fracture healing.
ObjectiveTo evaluate the feasibility and efficiency of one-stage external fixation by using locking plate in distal tibial fractures.MethodsIn this non-control prospective study, 28 patients with distal tibial fractures were included and underwent one-stage external fixation by using locking plate. There were 21 males and 7 females, with a mean age of 43 years (19–63). According to AO/OTA fracture classification, there were 9 cases of Type A1, 9 of Type A2, 10 of Type A3 fractures. There were 21 close and 7 open fractures. The locking plate was placed on the anteromedial aspect of the tibia with 4–5 bicortical screws inserted in both distal metaphysis and diaphysis. The radiographic and clinic results were evaluated.ResultsAll patients were followed up for the average of 16 months (ranging from 12 to 21 months). The average surgery duration was 38 (25–60) minutes. The mean time to fracture healing were 14.6 ± 2.67, 17.5 ± 3.66, and 18.4 ± 3.37 (p < 0.05) weeks in type A1, A2, and A3 fractures respectively. By the end of the follow-ups, the mean AOFAS score were 96.11 ± 2.32, 92.67 ± 1.80 and 92.00 ± 2.06 (p > 0.05) in type A1, A2, and A3 fractures respectively. None of nonunion, deep infection, or breakage of screw or plate were observed.ConclusionsDistal tibial fracture was the ideal indication for external fixation using locking plate. The external plating is characterized by ease of performance, less invasive, fewer soft tissue impingement, improved cosmesis, and convenient for removal.
The MR features of posttraumatic osteolysis are characteristic of this process. We advocate the use of MRI in patients with chronic AC joint pain who have had a prior AC joint dislocation, particularly if follow-up radiographs are nonspecific, equivocal, or do not indicate the presence of secondary osteoarthritis.
The surgical treatment of distal tibial fractures is still challenging. The purpose of this study was to evaluate the clinical and radiographic results associated with the use of a precontoured distal femoral locking plate as an external fixator in treating distal tibial fractures. From August 2011 to October 2012, 28 patients with distal tibial fractures were consecutively enrolled in this study. There were 9 OTA 43.A1, 9 43.A2, and 10 43.A3, including 21 closed and 7 open fractures. The precontoured distal femoral locking plate was placed on the anteromedial aspect of the tibia as an external fixator. All patients were followed for an average of 16 months. The mean surgical duration was 38 (25-60) minutes. The mean time until fracture healing was 16.7 (12-24) weeks. At final follow-up, the mean American Orthopaedic Foot and Ankle Society score was 93 (88-100). There were no nonunions, deep infections, or implant fractures. Three patients had transient superficial pin site infection, but these did not change the clinical outcome. External fixation using a precontoured distal femoral locking plate is a reliable option in treating distal tibial fracture. The procedure is easy to perform, is less invasive, and the low profile plate can be concealed under stockings and can be conveniently removed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.