ObjectiveTo explore the association between dynamic changes in red blood cell distribution width to platelet count ratio (RPR) during hospitalisation and short-term mortality in patients with sepsis.DesignA retrospective cohort study using propensity score matching.SettingIntensive care units (ICUs) of Beth Israel Deaconess Medical Center.ParticipantsA total of 8731 adult patients with sepsis were included in the study. The patients were identified from the ICU of the Medical Information Mart for Intensive Care database. The observed group included patients who experienced an increase in RPR of more than 30% during the first week of ICU admission, whereas the control group included the rest.Main outcome and measureUsing propensity score matching, a matched control group was created. The primary outcome was 28-day mortality, and the length of hospital stay and in-hospital mortality were the secondary outcomes.ResultsThe difference was evident in 28-day mortality between the two groups (85.8% vs 74.5%, p<0.001, Kaplan-Meier analysis, and HR=1.896, 95% CI=1.659 to 2.168, p<0.001, Cox regression). In the secondary outcomes, there was a significant difference in in-hospital mortality (p<0.001). In addition, the study discovered that the observed groups had a significantly longer hospital stay (p<0.001). Meanwhile, the results of subgroup analyses were consistent with those of the primary analyses.ConclusionsIn patients with sepsis, a significantly increased RPR is positively associated with the short-term death rate. Continuous RPR monitoring could be a valuable measure for predicting short-term mortality in patients with sepsis.
Background A tracheal foreign body is a common airway aspiration that creates an emergency, which often causes unobserved respiratory problems and requires management. Iatrogenic tracheal foreign bodies are rarely observed, which results in tracheal obstruction. If the foreign body were removed from the tracheobronchial system, it would save lives. A similar case of a tracheal foreign body was focused on, which was caused by medical glue used during preoperative computed tomography localization of pulmonary nodules. Case presentation The foreign body was deposited in the right upper bronchi, accidentally discovered after anesthesia when a double-lumen tube was located by fiber bronchoscopy. Following a video-assisted thoracoscopic surgery, the foreign body was removed using a respiratory endoscopy without subsequent adverse consequences for the patient. Conclusions There is a risk of complications from iatrogenic airway foreign bodies for preoperative localization of pulmonary nodules by injecting cyanoacrylate glue.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.