In a ground-source heat pump (GSHP) system, when the heating and cooling loads are not balanced, the ground temperature may migrate up or down after a few years of operation. This change in ground temperature can lower system efficiency because of the ineffective heat transfer temperatures. The present work contributes to fundamental understanding of thermal imbalance in borehole design. Long term ground temperatures were simulated using finite element methods to imitate the performance of GSHP systems. Borehole field configurations are explored and different aspect ratios of borehole layouts were compared. In addition, an alternative borehole configuration was studied, which involves alternating the length of individual boreholes within a single system. The results of the studies expressed potential in alleviating the effects of thermal imbalance by changing borehole field layout and potential in reducing borehole separation distance by altering individual borehole lengths.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.