Chicago Classification v4.0 (CCv4.0) is the updated classification scheme for esophageal motility disorders using metrics from high‐resolution manometry (HRM). Fifty‐two diverse international experts separated into seven working subgroups utilized formal validated methodologies over two‐years to develop CCv4.0. Key updates in CCv.4.0 consist of a more rigorous and expansive HRM protocol that incorporates supine and upright test positions as well as provocative testing, a refined definition of esophagogastric junction (EGJ) outflow obstruction (EGJOO), more stringent diagnostic criteria for ineffective esophageal motility and description of baseline EGJ metrics. Further, the CCv4.0 sought to define motility disorder diagnoses as conclusive and inconclusive based on associated symptoms, and findings on provocative testing as well as supportive testing with barium esophagram with tablet and/or functional lumen imaging probe. These changes attempt to minimize ambiguity in prior iterations of Chicago Classification and provide more standardized and rigorous criteria for patterns of disorders of peristalsis and obstruction at the EGJ.
Background
The functional lumen imaging probe (FLIP), measures esophagogastric junction (EGJ) distensibility (cross sectional area/luminal pressure) during volume-controlled distension. The aim of this study was to apply this tool to the assessment of the EGJ in untreated and treated achalasia patients and to compare EGJ distensibility with other diagnostic tools utilized in managing achalasia.
Methods
Findings from FLIP, high-resolution manometry (HRM), timed barium esophagram, and symptom assessment by Eckardt Score (ES) were compared in 54 achalasia patients (23 untreated, 31 treated). Twenty healthy volunteers underwent FLIP as a comparator group. The EGJ distensibility index (EGJ-DI) was defined at the ‘waist’ of the FLIP bag during volumetric distension, expressed in mm2/mmHg. The ES was used to gauge treatment outcome: good response < 3 or poor response ≥ 3.
Key Results
Of the 31 treated patients, 17 had good and 14 poor treatment response. The EGJ-DI was significantly different among groups, greatest in the control subjects and least in the untreated patients; patients with good treatment response had significantly greater EGJ-DI than untreated or patients with poor response. The correlations between EGJ-DI and ES and integrated relaxation pressure on HRM were significant.
Conclusion
The FLIP provided a useful measure of EGJ distensibility in achalasia patients that correlated with symptom severity. The measurement of EGJ distensibility was complementary to existing tests suggesting a potentially important role in the clinical management of achalasia.
Background & Aims
The aim of this study was to assess whether measurements of esophageal distensibility, made by high-resolution impedance planimetry, correlated with important clinical outcomes in patients with eosinophilic esophagitis.
Methods
Seventy patients with eosinophilic esophagitis (50 male, ages 18–68) underwent endoscopy with esophageal biopsy collection and high-resolution impedance planimetry using the functional lumen-imaging probe. The patients were followed prospectively for an average of 9.2 months (range 3–14 months), and the risk of food impaction, requirement for dilation; symptom severity during the follow-up period was determined from medical records. Esophageal distensibility metrics and the severity of mucosal eosinophilia at baseline were compared between patients presenting with and without food impaction and those requiring or not requiring esophageal dilation. Logistic regression and stratification assessments were used to assess the predictive value of esophageal distensibility metrics in assessing risk of food impaction, the need for dilation, and continued symptoms.
Results
Patients with prior food impactions had significantly lower distensibility plateau (DP) values than those with solid food dysphagia alone. Additionally, patients sustaining food impaction and requiring esophageal dilation during the follow-up period had significantly lower DP values than those who did not. The severity of mucosal eosinophilia did not correlate with risk for food impaction, the requirement for dilation during follow up, or DP values.
Conclusions
Reduced esophageal distensibility predicts risk for food impaction and the requirement for esophageal dilation in patients with eosinophilic esophagitis. The severity of mucosal eosinophilia was not predictive of these outcomes and had a poor correlation with esophageal distensibility.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.