BackgroundT2-Weighted (T2W) magnetic resonance imaging (MRI) pulse sequences have been used to detect edema in patients with acute myocardial infarction and differentiate acute from chronic infarction. T2W sequences have suffered from several problems including (i) signal intensity variability caused by phased array coils, (ii) high signal from slow moving ventricular chamber blood that can mimic and mask elevated T2 in sub-endocardial myocardium, (iii) motion artifacts, and (iv) the subjective nature of T2W image interpretation. In this work we demonstrate the advantages of a quantitative T2 mapping technique to accurately and reliably detect regions of edematous myocardial tissue without the limitations of qualitative T2W imaging.MethodsMethods of T2 mapping were evaluated on phantoms; the best of these protocols was then optimized for in vivo imaging. The optimized protocol was used to study the spatial, view-dependent, and inter-subject variability and motion sensitivity in healthy subjects. Using the insights gained from this, the utility of T2 mapping was demonstrated in a porcine model of acute myocardial infarction (AMI) and in three patients with AMI.ResultsT2-prepared SSFP demonstrated greater accuracy in estimating the T2 of phantoms than multi-echo turbo spin echo. The T2 of human myocardium was found to be 52.18 ± 3.4 ms (range: 48.96 ms to 55.67 ms), with variability between subjects unrelated to heart rate. Unlike T2W images, T2 maps did not show any signal variation due to the variable sensitivity of phased array coils and were insensitive to cardiac motion. In the three pigs and three patients with AMI, the T2 of the infarcted region was significantly higher than that of remote myocardium.ConclusionQuantitative T2 mapping addresses the well-known problems associated with T2W imaging of the heart and offers the potential for increased accuracy in the detection of myocardial edema.
Quantitative T2 mapping was recently shown to be superior to T2-weighted imaging in detecting T2 changes across myocardium. Pixel-wise T2 mapping is sensitive to misregistration between the images used to generate the parameter map. In this study, utility of two motion-compensation strategies—(i) navigator gating with prospective slice correction and (ii) nonrigid registration—was investigated for myocardial T2 mapping in short axis and horizontal long axis views. Navigator gating provides respiratory motion compensation, whereas registration corrects for residual cardiac and respiratory motion between images; thus, the two strategies provided complementary functions. When these were combined, respiratory-motion-induced T2 variability, as measured by both standard deviation and interquartile range, was comparable to that in breath-hold T2 maps. In normal subjects, this combined motion-compensation strategy increased the percentage of myocardium with T2 measured to be within normal range from 60.1% to 92.2% in short axis and 62.3% to 92.7% in horizontal long axis. The new motion-compensated T2 mapping technique, which combines navigator gating, prospective slice correction, and nonrigid registration to provide through-plane and in-plane motion correction, enables a method for fully automatic and robust free-breathing T2 mapping.
Aims Alpha-lipoic acid (LA) is a commonly used dietary supplement that exerts anti-oxidant and anti-inflammatory effects in vivo and in vitro. We investigated the mechanisms by which LA may confer protection in models of established atherosclerosis. Main Methods Watanabe heritable hyperlipidemic (WHHL) rabbits were fed with high cholesterol chow for 6 weeks and then randomized to receive either high cholesterol diet alone or combined with LA (20 mg/kg/day) for 12 weeks. Vascular function was analyzed by myography. The effects of LA on T cell migration to chemokine gradients was assessed by Boyden chamber. NF-κB activation was determined by measuring translocation and electrophoresis migration shift assay (EMSA). Key findings LA decreased body weight by 15 ± 5% without alterations in lipid parameters. Magnetic Resonance Imaging (MRI) analysis demonstrated that LA reduced atherosclerotic plaques in the abdominal aorta, with morphological analysis revealing reduced lipid and inflammatory cell content. Consistent with its effect on atherosclerosis, LA improved vascular reactivity (decreased constriction to angiotensin II and increased relaxation to acetylcholine and insulin), inhibited NF-κB activation, and decreased oxidative stress and expression of key adhesion molecules in the vasculature. LA reduced T cell content in atherosclerotic plaque in conjunction with decreasing ICAM and CD62L (L-Selectin) expression. These effects were confirmed by demonstration of a direct effect of LA in reducing T cell migration in response to CCL5 and SDF-1 and decreasing T cell adhesion to the endothelium by intra-vital microscopy Significance The present findings offer a mechanistic insight into the therapeutic effects of LA on atherosclerosis.
Phase contrast magnetic resonance imaging (PC-MRI) is used routinely to measure fluid and tissue velocity with a variety of clinical applications. PC-MRI methods require acquisition of additional data to enable phase difference reconstruction, making real-time imaging problematic. Shared Velocity Encoding (SVE), a method devised to improve the effective temporal resolution of PC-MRI, was implemented in a real-time pulse sequence with segmented echo planar readout. The effect of SVE on peak velocity measurement was investigated in computer simulation, and peak velocities and total flow were measured in a flow phantom and in volunteers and compared with a conventional ECG-triggered, segmented k-space phase-contrast sequence as a reference standard. Computer simulation showed a 36% reduction in peak velocity error from 8.8% to 5.6% with SVE. A similar reduction of 40% in peak velocity error was shown in a pulsatile flow phantom. In the phantom and volunteers, volume flow did not differ significantly when measured with or without SVE. Peak velocity measurements made in the volunteers using SVE showed a higher concordance correlation (0.96) with the reference standard than non-SVE (0.87). The improvement in effective temporal resolution with SVE reconstruction has a positive impact on the precision and accuracy of real-time PC-MRI peak velocity measurements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.