As a basic study of a practical method for predicting the sound insulation performance of windows, this report presents a study of the sound reduction index of windows with single glazing, below a critical frequency. First, the results calculated by an existing theory for a single plate for the sound reduction indices are compared with measured results of actual windows to assess the theory’s applicability for evaluating the sound insulation performance of windows. Then, a regression analysis is employed to measure the results of a certain number of actual windows to explore a further development of a more practical prediction. The following findings were obtained: (1) Sound reduction indices of actual fixed windows are predictable using Sewell’s transmission theory for a single plate. However, sound reduction indices of openable windows, especially those of sliding windows, are strongly affected by gaps in the window frame. Therefore, predicting sound reduction indices of all windows accurately is difficult if using only one theory. (2) The frequency slope of the window reduction index is much lower than that of the mass law. Regression analyses indicate that the frequency slope of the reduction index of all examined windows is 3.0 dB per octave, on average.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.