Spot-scanning particle therapy possesses advantages, such as high conformity to the target and efficient energy utilization compared with those of the passive scattering irradiation technique. However, this irradiation technique is sensitive to target motion. In the current clinical situation, some motion management techniques, such as respiratory-gated irradiation, which uses an external or internal surrogate, have been clinically applied. In surrogate-based gating, the size of the gating window is fixed during the treatment in the current treatment system. In this study, we propose a dynamic gating window technique, which optimizes the size of gating window for each spot by considering a possible dosimetric error. The effectiveness of the dynamic gating window technique was evaluated by simulating irradiation using a moving target in a water phantom. In dosimetric characteristics comparison, the dynamic gating window technique exhibited better performance in all evaluation volumes with different effective depths compared with that of the fixed gate approach. The variation of dosimetric characteristics according to the target depth was small in dynamic gate compared to fixed gate. These results suggest that the dynamic gating window technique can maintain an acceptable dose distribution regardless of the target depth. The overall gating efficiency of the dynamic gate was approximately equal or greater than that of the fixed gating window. In dynamic gate, as the target depth becomes shallower, the gating efficiency will be reduced, although dosimetric characteristics will be maintained regardless of the target depth.The results of this study suggest that the proposed gating technique may potentially improve the dose distribution. However, additional evaluations should be undertaken in the future to determine clinical applicability by assuming the specifications of the treatment system and clinical situation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.