The purpose of this study was to evaluate the effectiveness of the radiation
shield of radionuclide syringes and the personal dose equivalent by
performing a simulation of radionuclides used in nuclear medicine diagnosis.
In order to evaluate the dose depending on the distance between the radiation
source and the ICRU sphere against the thickness of the shielding device, the
distance at which a nuclear medicine worker may inadvertently come into
contact with radiation from the radiation source was set at 0 cm to 30 cm
according to the thickness of the shield, thus fixing the ICRU sphere. For a
dose evaluation, Hp(10), Hp(3), and Hp(0.07) measurable in specific depth of
the ICRU were evaluated. It was found that a dose measured on skin surface of
nuclear medicine workers was relatively higher, that the dose varied in
relation to the thickness of the radiation shield, and that the shielding
effect decreased for some radiation sources such as 67Ga and 111In. It proved
necessary to increase thickness of shielding device to the radiation sources
such as 67Ga and 111In. It is also considered that a study of proper
shielding thickness will be needed in future.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.