The relationship between humidity and dielectric constant for cement densified with small particles (DSP) has been studied in the relative humidity range 0%-93% and the frequency range 1 MHz to 1 GHz. The calculated dielectric constant appears to increase with increasing humidity as a linear relation at fixed frequency. According to experimental data and basic principles for dielectrics, two experimental expressions are suggested for heterogeneous dielectric materials to describe the observed behavior of the dielectric constant. The expressions fit the experimental data well in the frequency range studied. Apparent dielectric constant decreases with increasing frequency. Polarization of DSP cement is also discussed.
Atherosclerotic intracranial internal carotid artery stenosis (IICAS) is a leading cause of strokes. Due to the limitations of major cerebral imaging techniques, the early diagnosis of IICAS remains challenging. Clinical studies have revealed that arterial stenosis may have complicated effects on the blood flow’s velocity from a distance. Therefore, based on a patient-specific one-dimensional hemodynamic model, we quantitatively investigated the effects of IICAS on extracranial internal carotid artery (ICA) flow velocity waveforms to identify sensitive hemodynamic indices for IICAS diagnoses. Classical hemodynamic indices, including the peak systolic velocity (PSV), end-diastolic velocity (EDV), and resistive index (RI), were calculated on the basis of simulations with and without IICAS. In addition, the first harmonic ratio (FHR), which is defined as the ratio between the first harmonic amplitude and the sum of the amplitudes of the 1st–20th order harmonics, was proposed to evaluate flow waveform patterns. To investigate the diagnostic performance of the indices, we included 52 patients with mild-to-moderate IICAS (<70%) in a case–control study and considered 24 patients without stenosis as controls. The simulation analyses revealed that the existence of IICAS dramatically increased the FHR and decreased the PSV and EDV in the same patient. Statistical analyses showed that the average PSV, EDV, and RI were lower in the stenosis group than in the control group; however, there were no significant differences (p > 0.05) between the two groups, except for the PSV of the right ICA (p = 0.011). The FHR was significantly higher in the stenosis group than in the control group (p < 0.001), with superior diagnostic performance. Taken together, the FHR is a promising index for the early diagnosis of IICAS using carotid Doppler ultrasound methods.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.