We report the results of impaction bone grafting of the femoral side in revision total hip arthroplasty in Asian hips (South Korean patients) in which the surgery was performed with the Exeter stem. The minimum follow-up was 39 months (mean, 48.4; range, 39-66). There was subsidence of the cement-graft interface (<1 mm) in three hips (5%), of the stem-cement interface (<1 mm) in 12 hips (21%) and of the stem-cement interface (1-2 mm) in 14 hips (25%). Five hips (9%) developed intraoperative femoral fracture and two hips (4%) femoral perforation in revision. The complications of femoral fracture and subsidence did not have an adverse effect on the final clinical outcomes. The impaction of fresh-frozen allograft and use of a cemented, polished, tapered stem (Exeter stem) were also successful with good clinical and radiographic outcomes in our study of Asian hips (South Korean patients). However, we used smaller stems than the usual ones used for Western patients because of the smaller femur sizes.Résumé Nous reportons les résultats de la technique d'Exeter avec greffons impactés dans les reprises totales de hanche, étude réalisée sur des hanches asiatiques et sur des patients sud coréens, avec utilisation de la tige d'Exeter.Le suivi minimum a été de 39 mois (48.4 à 39.66). La migration à l'interface ciment greffe a été inférieure à 1 mm dans 3 cas, 5%. A l'interface tige ciment, (<1 mm) dans 12 hanches (21% des cas) et enfin à l'interface tige ciment, cette migration est comprise entre 1 et 2 mm dans 14 hanches (25% des cas). 5 hanches (11%) ont présenté durant l'intervention des complications avec une fracture fémorale dans 5 cas (9%) et une perforation fémorale dans 2 cas (4%). Ces complications ainsi que la migration de la tige n'ont pas entraîné de problèmes cliniques. La technique utilisant des allogreffes compactées cryoconservées et l'utilisation d'une tige cimentée et polie de type Exeter ont donné, dans cette étude, de bons résultats, tant sur le plan clinique que sur le plan radiographique. Cependant, nous avons dû utiliser des tiges beaucoup plus petites qu'habituellement en Europe compte tenu de la petite taille des fémurs asiatiques sud coréens.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.