We evaluated the diagnostic accuracy of two newly developed, point-of-care, rapid antigen tests (RATs) for detecting SARS-CoV-2, the AFIAS COVID-19 Ag and the ichromaTM COVID-19 Ag, and investigated antigen kinetics. A total of 200 serially collected nasopharyngeal (NP) specimens from 38 COVID-19 patients and 122 specimens from negative controls were analyzed. Diagnostic sensitivity and specificity were assessed in comparison to molecular test results and subdivided according to targeted genes (E, RdRP, and N) and days post-symptom onset (PSO). For the kinetics evaluation, cut-off-indices from serial NP specimens were used according to the number of days PSO. Both RATs showed sensitivity of 91.3‒100% for specimens with cycle threshold (Ct) < 25. The specificity of AFIAS was 98.7‒98.9% and that of ichromaTM was 100.0%. The kappa values of AFIAS and ichromaTM for the molecular testing of specimens with Ct < 25 (RdRP) were 0.97 and 1.00, respectively. The sensitivity of AFIAS and ichromaTM for all genes was lower for specimens collected at 8‒14 PSO than for those collected before 7-days PSO. The kinetics profiles showed that antigen levels gradually decreased from ≤ 7-days PSO to > 22-days PSO. Both RATs showed excellent specificity and acceptable sensitivity for NP specimens with higher viral loads and for specimens collected within 7-days PSO. Hence, they have the potential to become useful tools for the early detection of SARS-CoV-2. However, because of concerns about false negativity, RATs should be used in conjunction with molecular tests.
Filamentous fungi are a major cause of life-threatening infections in immunocompromised patients; thus, rapid and accurate identification is critical. Filamentous fungal identification by matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) has been demonstrated with high sensitivity and reproducibility; however, its wider application has been limited in clinical laboratories because of practical challenges such as database availability or lack of standardization.
We evaluated newly developed surrogate virus neutralization tests (sVNT) for detecting neutralizing antibodies (NAbs) against the receptor binding domain of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). VERI-Q SARS-CoV-2 Neutralizing Antibody Detection ELISA Kit (MiCo BioMed, Gyeonggi-do, Republic of Korea, hereafter, “eCoV-CN”) is an enzyme-linked immunosorbent assay-based sVNT, and VERI-Q SARS-CoV-2 Neutralizing Antibody Rapid Test Kit (MiCo BioMed, hereafter, “rCoV-RN”) is a point-of-care lateral-flow immunochromatography test with auto-scanner. A total of 411 serum samples were evaluated. Both evaluations used a 50% plaque reduction neutralization test (PRNT50) as the gold standard. Compared with PRNT50, the eCoV-CN showed 98.7% positive percent agreement (PPA), 96.8% negative percent agreement (NPA), 97.4% total percent agreement (TPA), with kappa values of 0.942. The rCoV-RN showed 98.7% PPA, 97.4% NPA, 97.8% TPA, and kappa values of 0.951, comparing to PRNT50. Neither assay indicated cross-reactivity for other pathogens, and the signal indexes were statistically significantly correlated to the PRNT50 titer. The two evaluated sVNTs show comparable performances to the PRNT50 with the advantages of technical simplicity, speed, and do not require cell culture facilities.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.