TAE using a mixture of absolute ethanol and iodized oil to improve visualization of endophytic renal masses facilitated tumor localization on unenhanced CT, permitting depiction of the tumor edge as well as a safe margin for ablation during CT-guided PCA, with an acceptable decline in renal function.
We report a case each of duodenorenal and colorenal fistula that arose after computed tomography-guided percutaneous cryoablation (PCA) for renal cell carcinoma and use imaging and endoscopic findings to analyze their causes and mechanisms. Both complications occurred though the edge of the iceball did not touch the intestinal wall, and patients' symptoms and fistula formation occurred several days after the PCA procedure. Based on imaging and endoscopy findings, we suspected the colorenal fistula resulted from bowel injury caused by ischemia from the occlusion of small vessels at the procedure's low temperature. Both cases were resolved conservatively without surgical intervention.
BackgroundScimitar syndrome can present with a wide clinical spectrum of symptoms either early in the neonatal period or later in life.Case descriptionWe report a case of a 62-year-old woman with anomalous systemic arterial supply to the basal lung with scimitar syndrome presenting as recurrent hemoptysis. Bronchoscopy revealed normal major bronchial branches without bronchial atresia, indicating that sequestration of the lung was not confirmed. The anomalous drainage of the scimitar vein was to the inferior vena cava, and an anomalous artery from the aorta supplied the right basal lung. There were no findings of pulmonary hypertension and arteriovenous malformation such as an anomalous artery to the scimitar vein. The distal portions of anomalous arteries were embolized using gelatin sponge particles and the proximal portion was embolized using fibered detachable coils. Although a small pulmonary infarction was observed as a complication, the patie
nt has not experienced any subsequence recurrence of the hemoptysis during a follow-up period of 6 months.Discussion and evaluationDeformities of the blood vessels and the lungs are frequently complex in scimitar syndrome. Although patients treated with surgical repair of this disorder may be at higher risk than those treated less invasively, we believe that transcatheter embolization was a useful strategy for the treatment of the anomalous systemic arterial supply to the basal lung, particularly in this patient with scimitar syndrome.ConclusionHemoptysis in a patient with scimitar syndrome associated with anomalous systemic arterial supply to the basal lung was successfully treated with transcatheter arterial embolization. However, it might be better to avoid the use of gelatin sponge particles in patients with a similar anomaly without pulmonary artery distribution because of the possibility of causing severe pulmonary infarction.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.