A multi-connected floating body system composed of many connected small-scale floating body units has a number of advantages with regard to construction and performance. To realize the multi-connected floating body system, a new type of mechanical connecting device was developed. It is composed of multi-degrees of freedom connecting mechanism and restricting mechanism to control a restricting condition between floating body units, and its effectiveness was confirmed by model basin test in waves. Next, friction and wear tests in the seawater environment led to the discovery of suitable materials for oscillatory sliding parts in multi-degrees of freedom connecting mechanism. Finally, a field test performed for two floating body units connected by use of the mechanical connecting device proved that the developed mechanical connecting device was of practical use.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.