Background This study aimed to compare surgically induced astigmatism (SIA) on the anterior and total cornea during cataract surgery through a 2.2 mm steep meridian incision. Methods The study included 69 left eyes of 69 patients who had undergone cataract surgery. The 69 eyes were classified into three subgroups according to the preoperative steep meridian. Following phacoemulsification, an intraocular lens was inserted into the bag. The keratometric measurements were taken 12 months postoperatively, on the anterior cornea (automated keratometer and anterior keratometry [K] from a rotating Scheimpflug camera) and total cornea (equivalent K reading [EKR] 3.0 mm, EKR 4.5 mm, total corneal refractive power (TCRP) 2.0 mm ring, TCRP 3.0 mm zone, TCRP 4.0 mm zone). The SIA was analyzed for each parameter. Results On the double-angle polar plot, the summated vector mean values of SIA determined by the automated keratometer and Scheimpflug anterior K were 0.28 diopter (axis: 177°) and 0.37 diopter (axis: 175°) in with-the-rule (WTR) astigmatism; 0.03 diopter (axis: 156°) and 0.18 diopter (axis: 177°) in oblique astigmatism; 0.15 diopter (axis: 96°) and 0.17 diopter (axis: 73°) in against-the-rule (ATR) astigmatism. The mean SIAs on the total cornea ranged from 0.31 to 0.42 diopter in WTR astigmatism; from 0.16 to 0.27 diopter in oblique astigmatism; from 0.04 to 0.11 diopter in ATR astigmatism. Mean magnitude SIA ranged from 0.41 to 0.46 diopter on anterior corneal surface and 0.50 to 0.62 diopter on total cornea. J0 and J45 of the posterior cornea showed no significant changes after cataract surgery, and the changes in J0 and J45 did not show any statistical differences between the anterior and total cornea (all p > 0.05). Conclusions There were no differences in the summed vector mean values of SIA between the anterior cornea and the total cornea.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.