A new DK-decreasing test method of the metal film was developed. The film was adhered to a through elliptical hole in a base plate and was fatigued in accordance with the displacement constraint along the hole -circumference in the base plate subjected to a cyclic stress. Commonly, a stress intensity factor range was increased with a crack propagation under a constant stress amplitude but was decreased toward the hole-edge because of the difference in thickness between the film and the base plate in this DK-decreasing test method.The decrease in a stress intensity factor with a crack propagation was calculated by FEM analysis and the optimum aspect ratio of an elliptical hole was determined. Using the DK-decreasing test method, the crack propagation test was conducted for metal films. As a result, the fatigue crack propagation rate was decreased and was arrested near the hole-edge under the constant stress amplitude to the base plate. The threshold stress intensity factor ranges were obtained for some kinds of metal film and the accuracy of the testing method was discussed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.