Background. The relationship between inflammatory bowel disease and gut microbiota is inextricable. Electroacupuncture (EA) can alleviate acute experimental colitis, but the performance of intestinal microorganisms and the mechanism are still not fully understood. We investigated the relationship between the EA and gut microbes and clarified the role of tight junction and adiponectin in the anti-inflammatory effect of EA. Methods. Male C57BL/6 mice were randomized into three groups: normal control, dextran sulfate sodium- (DSS-) induced ulcerative colitis (DSS), and DSS with EA ST36 (DSS + EA). Mice body weight, DAI score, colon length, and histological score were evaluated for colitis severity. Colonic inflammation and tight junctions were demonstrated by the immunohistochemical (IHC) method. Systemic responses were confirmed by plasma cytokines and adiponectin with multiplex immunoassays. Gut microbiome profiling was conducted by 16S rRNA gene sequencing. Results. EA had benefit in relieving both macroscopic and microscopic colonic inflammation. It can reduce disease activity, maintain colon length, and ameliorate histological inflammatory reaction. In IHC stain, EA decreased CD11b, F4/80, TLR4, and MyD88 and preserved claudin-1 and ZO-1 expression. Compared with the control group, the DSS group showed elevated levels of CRP, IFN-γ, TNF-α, and IL-6, but decreased adiponectin. These changes were reversed by EA, accompanied by modulation of the overall structure of gut microbiota. Conclusion. Our findings suggest that EA exerts its therapeutic effect by TLR4 signaling via the MyD88-dependent pathway. EA could increase adiponectin, maintain mucosal tight junctions, and modulate gut microbiota.
Background Chronic low back pain is a common problem and is associated with high costs, including those related to health care and indirect costs due to absence at work or reduced productivity. Previous studies have demonstrated that acupuncture or electroacupuncture can relieve low back pain. Electronic acupuncture shoes (EAS) are a novel device designed in this study. This device combines the properties of acupuncture and transcutaneous electrical nerve stimulation for clinical use. Objective The aim of this study was to evaluate the efficacy of EAS in patients with chronic low back pain. Methods In this prospective double-blinded randomized controlled study, the data of 83 patients who experienced chronic low back pain were analyzed. Patients came to our clinic for 20 visits and underwent assessment and treatment. Patients were randomly allocated to receive either EAS plus placebo nonsteroidal anti-inflammatory drugs (NSAIDs) (EAS group, n=42) or sham EAS plus NSAIDs (NSAID group, n=41). The visual analog scale (VAS) score and range of motion were assessed at baseline, before and after each EAS treatment, and 2 weeks after the last treatment. The time for achieving pain remission was recorded. Quality of life was assessed at the 2nd, 14th, and 20th visits. Results After 6 weeks of treatment, the treatment success rate in each visit in the EAS group was higher than that in the NSAID group, as revealed by the intention-to-treat (ITT) and per-protocol (PP) analyses, but significant differences were observed only during the 16th visit in the ITT analysis (EAS group: 31/37, 84% and NSAID group: 21/34, 62%; P=.04). The change in the VAS score from baseline in each visit in the EAS group was greater than that in the NSAID group, as revealed by the ITT and PP analyses, and significant differences were observed in the 5th visit and 9th visit in the ITT analysis (P=.048 and P=.048, respectively). Significant differences were observed in the left rotation in the 2nd visit and 4th visit (P=.049 and P=.03, respectively). No significant differences were observed in the VAS score before and after treatment in each visit and in the quality of life in both groups. Conclusions EAS might serve as a reliable alternative therapeutic tool for patients with chronic low back pain who are contraindicated for oral NSAIDs. Trial Registration ClinicalTrials.gov NCT02468297 https://clinicaltrials.gov/ct2/show/NCT02468297
Background The Auto Manipulation Device for Acupuncture (AMDA) is designed for providing stable, quantified effects and higher frequency when doing lifting and thrusting manipulation. The purpose of this study is to investigate the safety of manipulation by AMDA in different frequency and duration in healthy rats. Methods The study was divided into two parts: single intervention and once a day for a week. 12 rats and 15 rats were randomly allocated to different groups: Control (needle insertion only), AMDA (2Hz/10Mins), AMDA (2Hz/20Mins), AMDA (20Hz/10Mins), and AMDA (20Hz/20Mins) for single and repeated interventions. Real-time physiological functions, laboratory data, and the bilateral muscle tissue of acupoint (ST 36) were obtained after the intervention. Results We found neither real-time physiological functions nor laboratory data differences between control group and AMDA groups in both parts. In the muscle tissue samples, the slight damage had been observed in the AMDA group with a frequency of 2 Hz for 20 minutes after once intervention, and the repeated session groups noted more obvious tissue damage with fibrotic change. Although the period was shorter, higher frequency manipulation caused more damage that fibroblast nuclei became more slender and obvious. However, no significant adverse effect was noted such as crippled and molting in the whole process. Conclusion Our study suggested that the safety issue of AMDA operation in rats is feasible because there was no difference between control group and AMDA groups among real-time physiological functions and laboratory data. However, manipulation with higher frequency should be more preserved.
BACKGROUND Chronic low back pain is a common problem and is associated with high costs. Previous studies have demonstrated that acupuncture or electroacupuncture can relieve low back pain. Electronic acupuncture shoes (EAS) are a novel device designed in this study. This device combines the properties of acupuncture and transcutaneous electrical nerve stimulation (TENS) for clinical use. OBJECTIVE The present study evaluated the efficacy of EAS in patients with chronic low back pain. METHODS In this prospective, randomized, controlled double-blinded study, the data of 83 patients who experienced chronic low back pain were analyzed. Patients came to our clinic for 20 visits and received assessment and treatment. Patients were randomly allocated to receive either EAS plus placebo nonsteroidal anti-inflammatory drugs (NSAIDs) (Group EAS, n = 42) or sham EAS plus NSAIDs (Group NSAIDs, n = 41). The visual analog scale (VAS) score and range of motion were assessed at baseline, before and after each EAS treatment, and 2 weeks after the last treatment. The time for achieving pain remission was recorded. Quality of life was assessed at 1st, 14th, and 20th visits. RESULTS After 6 weeks of treatment, the treatment success rate (TSR) in each visit in the EAS group was higher than that in the NSAID group, as revealed by the intention to treat (ITT) and per protocol (PP) analyses, and significant differences were observed only in visit 16 in the ITT analysis (EAS group: 83.8% and NSAID group: 61.8%, P = .036). The change in the VAS score from baseline in each visit in the EAS group was higher than that in the NSAID group, as revealed by the ITT and PP analyses, and significant differences were observed in visit 5 and visit 9 in the ITT analysis (P = .048 and .048, respectively). Significant differences were observed in left rotation in visit 2 and visit 4. No significant differences were observed in the VAS score before and after treatment in each visit and in quality of life in both groups. CONCLUSIONS EAS might serve as a reliable alternative therapeutic tool for patients with chronic low back pain who are contraindicated for oral NSAIDs. CLINICALTRIAL ClinicalTrials.gov NCT02468297; https://clinicaltrials.gov/ct2/show/NCT02468297
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.