Transformer winding hot-spot temperature (HST) is one of the important factors affecting transformer oil-paper insulation deterioration. This study presents a three-dimensional coupled electromagnetic-fluid-thermal analysis method for HST calculation in a 10 kV oil-immersed distribution transformer, the influence of the transformer internal metal structure parts on the HST of the winding is considered in the simulation. Combining electromagnetic-field calculation with no-load test and load test of the transformer provides a more accurate method to determine internal losses of the transformer. Taking those power losses as heat sources, the transformer fluid-thermal field analysis is conducted with the finite volume method. The variation of physical parameters of transformer oil with temperature is considered in the simulation. On the basis of the equivalent thermal resistance theory, the equivalent thermal conductivities of transformer windings are obtained. The simulation results deduced from the proposed method agree well with the experimental ones, which are obtained with fibre optic temperature sensors during the transformer temperature rise test, the maximum temperature difference is <3°C. The results validated the validity and accuracy of the proposed transformer HST calculation method.
Restricted by cultivated land vegetation, road construction, and land acquisition compensation costs, the grounding electrode extension method is not applicable for grounding resistance reduction of some wind turbines in limited areas. A new grounding resistance reduction method is proposed and verified for wind turbines by connecting nearby wind turbine grounding grids. To study the efficiency of the proposed method, the grounding characteristics of connected grounding grids are calculated. Simulation results indicate that the grounding resistance of connected grounding grids is smaller than that of box extension grounding grids. The grounding characteristics of the grounding grid connection are affected by grounding current frequency and material parameters. The grounding grid connection increases the current dispersion area and reduces the ground potential rise of the grounding conductor.
During the long-term operation of electrical equipment, the insulation performance of applied SF6 gas may be affected by humidity, pressure, and temperature. In this study, the collision cross sections of SF6 and H2O are considered, including ionization, attachment, excitation, and elastic collision. In order to analyze the influencing factors of SF6 insulation performance, discharge parameters are computed by the Boltzmann equation under different environmental conditions, including humidity, pressure, and temperature. It is concluded that with the conditions of 0.1 MPa and 300 K, the critical breakdown electric field increases by 1.23 kV/cm as the relative humidity increases from 0% to 80%. As the pressure increases from 0.1 to 0.6 MPa, the critical breakdown electric field increases by 451.07 kV/cm. However, temperature also has little effect on the insulation performance of SF6 gas. The conclusions of this study have reference value for safe and stable operation of SF6 insulated power equipment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.