Background: Fatty infiltration of the rotator cuff muscles is highly related to poor outcomes after rotator cuff tears. Fat fraction (FF) based on traditional 2–dimensional measurements (2D-FF) from a single sagittal Y-view slice cannot determine intramuscular FF in the rotator cuff muscles; the newly developed 3–dimensional method (3D-FF) is supposed to precede 2D measurements for intramuscular FF evaluation in accuracy and reliability. Purpose: (1) To measure 3D-FF and (2) to compare 3D-FF and 2D-FF in terms of quantitative values and intra- and interobserver agreement. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: Six-point Dixon magnetic resonance imaging was performed in patients with full–thickness supraspinatus tears. 2D-FF was calculated on a single sagittal Y-view. Semiautomatic segmentation software (ITK-SNAP) was used to reconstruct 3D volumes of the supraspinatus muscle and fat. 3D-FF was obtained by dividing the fat volume by the total volume of the supraspinatus muscle. A paired t test was used to compare the individual differences between 2D-FF and 3D-FF results. Linear regression and Bland-Altman analyses were performed to determine the agreement between 2D-FF and 3D-FF. Intraclass correlation coefficients (ICCs) were calculated to determine intra- and interobserver agreement. Results: The 3D muscular and fatty models presented an inhomogeneous distribution of intramuscular fat in the supraspinatus, indicating the superiority of 3D-FF over 2D-FF in capturing all muscle morphologic information. 2D-FF was significantly higher than 3D-FF in the supraspinatus with large (19.5% ± 5.9% vs 16.2% ± 3.7%; P = .002) and massive (34.8% ± 13.3% vs 26.2% ± 9.4%; P < .001) rotator cuff tears. 2D-FF overestimated the FF compared with 3D-FF by >50% in 14.7% of all patients and by >15% in 67.6% of patients with large or massive RCTs. The discrepancy between 2D-FF and 3D-FF increased with increasing mean FF. The intra- and interobserver agreement of 3D-FF (ICCs, 0.89-0.99 and 0.89-0.95) was superior to that of 2D-FF (ICCs, 0.71-0.95 and 0.64-0.79). Conclusion: 3D-FF indicated an inhomogeneous distribution of intramuscular fat by capturing all muscle and fat morphologic information. In patients with large and massive rotator cuff tears, 2D-FF of the supraspinatus was significantly higher than 3D-FF. 3D-FF was more reliable than 2D-FF for estimating fatty infiltration in the supraspinatus, with better intra- and interobserver agreement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.