A recycled aggregate concrete (RAC) with different replacement percentages of recycled coarse aggregates (RCAs) (i.e. 0, 30, 50, 70, 100%) was investigated experimentally at elevated temperatures. The residual compressive strength as well as the residual flexural strength of the RAC following elevated temperatures was studied and evaluated. A relationship between the residual compressive flexural strength of RAC and the elevated temperature was proposed. Furthermore, the relationship between the residual flexural strength and the compressive strength of the RAC was compared and analysed. It was found that both the residual compressive strength and the residual flexural strength of the RAC decrease with a rise in temperature, and the effect of the RCAs replacement percentage on the residual flexural strength and the residual compressive strength of RAC was found to be obvious.
To shorten the duration of construction and reduce the costs, identifying the number of floors supported by scaffolds is necessary to construct a multi-story building with the floors plate of long-span open-web sandwich slab, composed of the upper and lower ribs, shear key, and surface sheet. This study proposes a favorable method of two-stage construction support floors, namely the construction stages I and II, by establishing their finite element models that consider the effect of the horizontal tube constraining the upright tube in scaffolds. Furthermore, to ensure accuracy of the model in construction stage II, the full-hall supports of the first floor in construction stage I are equalized to uniform surface loads, and then the two construction processes are simulated by considering the upright tubes of the scaffolds and the structure. Comparison of the two modeling results with field-measured data shows that the equivalent methods of the upright tube and the fullhall supports are feasible. In addition, for an open-web sandwich floor slab whose span is ≤24.00m, only the full-hall supports of the floor can be retained if its lower floor is the basement roof; otherwise, the full-hall supports should be retained both on this floor and its lower one. When the span of the floor slab is 39.00m and if the span of the lower two floors slab is ≤24.00m, reaching the concrete design strength, then the full-hall supports should be retained on this floor and the lower floor, and partial re-supports should be applied to the second lower floor.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.