SummaryThrombomodulin, TM, is an endothelial cell membrane protein acting as a cofactor for the activation of plasma protein C. Soluble TM is present in plasma and urine of normal subjects. Enzyme immunoassay, EIA, for human TM was developed using mouse monoclonal antibodies against human placental TM in this paper. We obtained four types of the monoclonal antibodies against human placental TM. EIA sandwich method using three types of the monoclonal antibodies enabled us to measure almost all of 6 and 7 TM subspecies in plasma and urine, respectively, except 1 subspecies, 31 kDa TM. There was no interference from other components of plasma and urine in the assay conditions. Titration curves of purified TM in buffer or in normal plasma were linear within the range from 0.08 to 10 ng/ml. The coefficient of variation at 0.08 ng/ml TM was 4.7%. TM titer with buffer, assayed by this method, was reduced by the addition of thrombin at the final concentration of 20 U/ml, but the titer with plasma was not reduced even at 100 U/ml. These concentrations of thrombin are far larger than those which would be formed in circulation. TM levels in plasma and urine of normal subjects collected in the morning were 35.2 ± 8.32 ng/ml (n = 346) and 111 ± 31.6 ng/ml (n = 33), respectively. TM level in plasma did not differ from the level in serum. Circadian fluctuation of plasma TM was not significant in 10 normal adults, although a tendency of increase in TM excretion to urine was found rather in the day time than the other times. It was concluded that this EIA is reliable for TM assay in human plasma and urine, which will reflect activation or injury of endothelial cells.
The effect of total-body cold exposure on plasma concentrations of von Willebrand factor (vWF), endothelin-1 (ET) and thrombomodulin (TM), all of which are considered to be generated from the endothelium, was studied in systemic lupus erythematosus (SLE) patients with and without Raynaud’s phenomenon. The plasma levels of vWF, ET and TM in SLE patients, irrespective of the presence of Raynaud’s phenomenon, were significantly higher than in normal controls even before the cold provocation test. After the cold provocation test, plasma levels of vWF and ET were significantly higher in SLE patients with Raynaud’s phenomenon than in those without and in normal controls. No significant increase in TM was observed in either the SLE patients or the controls. These results suggest that SLE patients, regardless of the presence of Raynaud’s phenomenon, are in a hypercoagulable state and that this state may be further intensified by cold exposure. Hence, it is concluded that we should consider antithrombotic therapy for SLE patients, especially those with Raynaud’s phenomenon, to prevent unwanted activation of the coagulation system and possible endothelial damage.
This report describes the distribution and localization of thrombomodulin (TM) in the rat eye by light and electron microscopic immunocytochemistry. In addition to the endothelium of the entire vasculature, TM was found on the non-vascular structures lining the cavities of the posterior and anterior chambers and the limbus. TM was localized on the basal, lateral, and apical plasma membranes of the inner and outer ciliary epithelium, and the posterior iris epithelium in which there was no polarized expression of TM. In the anterior chamber, TM was localized on the luminal surface of the corneal endothelium, but was negative on the anterior border layer of the iris, which is composed of a discontinuous layer of fibroblasts and collagen fibers. Thus, TM was present at sites of cell-to-cell contact. TM was also present on the endothelia of the trabecular meshwork and the Schlemm's canal in the limbus. TM was localized not only on the luminal plasma membrane, but also on the cytoplasmic giant vacuoles in the endothelial cells of the Schlemm's canal. These findings extend the importance of anticoagulant mechanisms to the systems of secretion, circulation, and drainage of the aqueous humor.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.