The IcareHOME can be used as a self/home-tonometer; however, it may result in lower IOP values.
PurposeWe investigated the incidence of prostaglandin-associated periorbitopathy (PAP) in subjects with glaucoma treated with latanoprost ophthalmic solution.Subjects and methodsOne eye and the forehead in 22 subjects were evaluated. All patients had used latanoprost for more than 1 year (range, 12 to 45 months; mean, 26.0 months) and were prostaglandin F2α analogue treatment-naïve. Digital photographs of the subjects obtained before latanoprost therapy and at the last examination were compared retrospectively. Four signs of PAP (deepening of the upper eyelid sulcus (DUES), upper eyelid ptosis, flattening of the lower eyelid bags, and inferior scleral show) and supplemental side effects around the eyelids (eyelash growth, poliosis, and eyelid pigmentation) were judged to be negative or positive by three independent observers. If the observers unanimously rated a sign as positive, the result was defined as positive.ResultsTwelve subjects (54.5%) had no apparent signs. Three subjects were judged to have DUES (13.6%), and two subjects each were judged to have flattening of the lower eyelid bags and eyelid pigmentation (9.0%). The other signs were judged as positive in only one subject each, respectively (4.5%). A univariate logistic regression analysis showed no significant associations between any of the signs and age, sex, or the duration of therapy.ConclusionLatanoprost induced DUES, upper eyelid ptosis, flattening of the lower eyelid bags, inferior scleral show, and supplemental side effects around the eyelids; however, the rates of such occurrence might be relatively low.
Conjunctival hyperemia induced by ripasudil 0.4% peaks rapidly to moderate severity, but subsides relatively quickly.
Purpose: We evaluated the agreement between the intraocular pressure (IOP) values of new rebound tonometer, Icare ic100, and Icare TA01i or Goldmann applanation tonometer (GAT). Methods: We studied one eye each of 106 subjects (57 with primary open-angle glaucoma, 49 healthy subjects). IOP was randomly measured twice with the patient in sitting position using the Icare ic100, Icare TA01i, and GAT. Tonometer measurements were evaluated using Bland-Altman analysis. The relationship between IOP difference (Icare ic100-GAT) and age, sex, disease, axial length, central corneal thickness (CCT), and corneal curvature was investigated using multivariate regression analysis. Results: IOPs measured using Icare ic100, Icare TA01i, and GAT were 11.7±3.0 (mean±standard deviation), 12.2±2.9, and 16.0±3.2 mm Hg, respectively (P<0.001, one-way analysis of variance). Icare ic100 showed significantly lower IOPs than GAT (P<0.05), but not than Icare TA01 (P>0.05; Tukey-Kramer test). Bland-Altman analysis revealed that the mean differences between Icare ic100 and Icare TA01i and those between Icare ic100 and GAT were −0.46 and −4.2 mm Hg, respectively (95% limits of agreement, −3.35 to 2.42 and −10.10 to 1.61 mm Hg, respectively). For IOP differences between Icare ic100 and GAT, parameters selected in the optimal model were CCT (coefficient, 20.3, P=0.029), corneal curvature (3.0, P=0.020), and glaucoma-normal (−1.0, P=0.004). Conclusions: The new rebound tonometer Icare ic100 almost constantly showed IOPs lower than GAT. The difference was affected by CCT, corneal curvature, and disease.
PurposeModern cataract surgery is generally considered to bring about modest and sustained intraocular pressure (IOP) reduction. However, the pathophysiological mechanism for this remains unclear. Moreover, a change in ocular biomechanical properties after surgery can affect the measurement of IOP. The aim of the study is to investigate ocular biomechanics, before and following cataract surgery, using Corvis ST tonometry (CST).Patients and methodsFifty-nine eyes of 59 patients with cataract were analyzed. IOP with Goldmann applanation tonometry (IOP-G), axial length, corneal curvature and CST parameters were measured before cataract surgery and, up to 3 months, following surgery. Since CST parameters are closely related to IOP-G, linear modeling was carried out to investigate whether there was a change in CST measurements following cataract surgery, adjusted for a change in IOP-G.ResultsIOP-G significantly decreased after surgery (mean±standard deviation: 11.8±3.1 mmHg) compared to pre-surgery (15.2±4.3 mmHg, P<0.001). Peak distance (the distance between the two surrounding peaks of the cornea at the highest concavity), maximum deformation amplitude (the movement of the corneal apex from the start of deformation to the highest concavity) and A1/A2 velocity (the corneal velocity during inward or outward movement) significantly increased after cataract surgery (P<0.05) while radius (the central curvature radius at the highest concavity) was significantly smaller following cataract surgery (P<0.05). Linear modeling supported many of these findings, suggesting that peak distance, maximum deformation amplitude and A2 velocity were increased, whereas A2 deformation amplitude and highest concavity time were decreased (after adjustment for IOP change), following cataract surgery.ConclusionCorneal biomechanical properties, as measured with CST, were observed to change significantly following cataract surgery.Trial registrationJapan Clinical Trials Registry UMIN000014370
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.